4 electrical installation, 1 installation with 2-way coupler with terminator – NORAC 5465BC-NT User Manual

Page 10

Advertising
background image



7

4 Electrical Installation

The outer wing sensors will have been installed with either a 2-way coupler with terminator
(NORAC part number 43764T [E20]) or a 3-way coupler and a terminator plug (NORAC part
numbers 43760 and 43764 [E10 & E20]). Determine which type is installed and follow the
appropriate set of instructions.

4.1 Installation with 2-Way Coupler with Terminator

1. Remove the 2-way coupler with terminator (E20) from the outer sensor and install it at the

inner sensor.

2. Install the 3-way coupler (E10) at the outer sensor. Plug the existing CANbus cable (C05)

and the sensor cable into the 3-way coupler.

3. Connect the CANbus cable (C06) between the 2-way coupler with terminator (E20) and

the 3-way coupler (E10).

Only the components shown in black are included in this kit.

Figure 6: Electrical Installation: 2-Way Coupler with Terminator