Installation Instructions

Model Number 1075-AP135

(877) 867-2312www.oberonwireless.com

Rev. A2 05/23/13

Oberon, Inc. •••• 1315 South Allen Street •••• State College, PA 16801

Copyright 2012



Assembly Components:
- Ceiling enclosure Model 1075-AP135 assembly – 1 each
- Ceiling tile bridge – 2 each
- #8-32 X 1/4 “ screw –4 each
- #8-32 nut – 4 each
- 3/4” Trade Size Cable Clamp – 1 each
- Keys for access door lock – 2 each
- Support wire – 4 each
- Fire Block Foam – 1 each

If any of these items are missing, contact your Oberon representative.


Find a flat work surface to assemble the ceiling
enclosure
, access point and antenna(s) prior to
mounting in ceiling.


Step 1 - Cut a 13” x 13” opening in the center of a
ceiling tile (not included – ref. Figure 1).














Step 2 – Place the ceiling enclosure assembly on the
work surface. Remove one of the 1” trade size hole
cover on the side of the enclosure and install the 1”
conduit nipple (the side on which the conduit nipple is
to be installed will be determined by the location the
enclosure is to be installed and direction from which
conduit will be brought into the enclosure – ref. Figure
2
).





Page 2


Step 3 –Lay ceiling tile over the
enclosure assembly such that
the previously cut opening in the
ceiling tile is equally spaced
around the outside of the
enclosure (ref. Figure 3). Place
the ceiling tile bridges along
each side of the enclosure and
attach using a #8-32 screw.
Prior to tightening, be sure to
properly align the tile bridges so
the ends of the tile bridges align
with the outside edge of the
ceiling tile. Once the tile bridges
are properly aligned, press the
shoulder of the tile bridge down
firmly against the tile and then
securely tighten the screws.
This is to assure that there is
minimal gap between the
enclosure’s flange and the
ceiling tile once it is placed in
the ceiling. The four (4) holes on
the tile bridge will be used to
secure the enclosure with grid
wires.


Step 4 – Install the
mounting plate onto the
mounting bracket using
the (4) # 4-40 screws. The
tabs of the mounting plate
should

be

facing

up

toward the cutout on the
bracket. Slide the access
point onto the mounting
plate, locking the tabs to
the

underside

of

the

access point The door
assembly is completed by
attaching

the

previously

assembled

mounting

plate/access point assembly
to the enclosure door by
securing it in place with four
(4) #8-32 hex nuts. Place the
slotted holes in the mounting
plate/access point assembly
over the studs located on the bottom side of the door (NOTE: the mounting plate can only be attached to the door in one direction. If the
slotted holes don’t match up with the studs in the door, rotate the mounting plate 180°). Once the mounting plate is positioned, secure it in
place by installing four (4) #8-32 hex nuts (Figure 5).

Page 3

Figure 2 - Hardware installation.

Figure 3 - Installation to ceiling tile.

Figure 5 – Exploded door view.

This product is Listed by Underwriters

Laboratories Inc. Representative

samples of this product have been

evaluated by UL and meet applicable

safety standards.

File #E348543