Warning, Installation instructions – Oberon 1076-AP135 User Manual

Page 2

Advertising
background image

Figure 6

Figure 5 – Exploded door view.


Step 5 –Unlock and open the door. Attach Cisco AIR-AP-BRACKET-1 for the 1140/3500 series APs or Cisco AIR-AP-
BRACKET-2 for the 2600/3600 series APs
to the door bracket with (4) #8-32 screws. Next, slide the access point onto the
Cisco bracket. Secure the door bracket to the door using the (4) #10-32 nuts provided (ref. Figure 5).

Step 6 – Once the assembly has been installed in the wall or ceiling and secured using wall bridges, open the door and run
the Ethernet cable into the enclosure through the conduit connector located on the side of the access point enclosure and
attach to the access point prior to installing. Insert foam into the conduit connector and pull the data cable through far enough
to allow attachment to the access point (8" - 10"). Tighten cable clamp around foam fire block so that there are no air gaps. Be
careful not to over tighten and crush the Ethernet cable(s). Reference Figure 6.

Step 7 – Once the access point is secured and power and Ethernet are connected, lock the door. The installation is now
complete.

If Placing Enclosure In A Ceiling

Step 8 If placing enclosure into a ceiling remove the (4) screws in the corner of the backbox and thread the (4) eyebolts
(included) into the backbox and lock into place using the (4) eyebolt nuts (included). Attach the hanger wires to the eyebolts
and then to a permanent structure within the ceiling.













Page 4

MODEL 1076-AP135

Installation Instructions

**** WARNING ****

Please thoroughly read the product warning below

before installation to provide for a safe work

environment.

1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical

Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or
other means must be used for the installation of this product in the ceiling. Acoustical, suspended, false, drop and
concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with
independent support wires, wire rope, threaded rod, or other secure support means of adequate gauge and fire
resistance.

2. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door

from accidentally swinging open.

3. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.

4. This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not

exceed this temperature, depending on power dissipation within enclosure.


5. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be

maintained for the safe operation of the equipment.


6. This product is intended to be installed by trained personnel.

7. Only Listed ITE products and Listed AC Receptacles shall be installed within the enclosure.

8. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or

replacement.


9. Maximum weight to be installed in the unit is 25 lbs.

10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that

complies with UL 2043 or UL 1479.


11. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.

12. If AC power is used inside the enclosure, connect the ground wire to the green ground screw located near the

knockout in the backbox.


Page 1

Advertising