Oberon 1028-04-ANT5-F User Manual

Installation instructions

Advertising
background image

Installation Instructions

Model Number 1028-04-ANT5-F

(877) 867-2312www.oberonwireless.com

Rev. 2 06/24/14

Oberon, Inc. •••• 1315 South Allen Street •••• State College, PA 16801

Copyright 2014

Figure 1

Figure 2

Figure 3

Assembly Components:
- Enclosure Model 1028-04-ANT5-F assembly – 1 each
- Hanger Wire – 8 each
- 8-32 Nuts – 4 each
- Keys for access door lock – 1 each
- Installation Instructions – 1 each
- T-bar Bracket – 1 each
- 1" Trade Size Hole Plugs – 3 each
- 1/2" Trade Size Hole Plugs – 4 each


If any of these items are missing, contact your Oberon representative.

Find a flat work surface to assemble the enclosure and any other network/cellular components prior to mounting in ceiling.



Step 1 – Place the enclosure assembly back side down on the work surface and keyed doorway unlocked. Remove the desired number of
hole plugs on the sides and door of the enclosure if they are already installed.

**IMPORTANT** - Determine the correct access point installation method based on the manufacturer.

Step 2a(For Cisco AP’s Only) The mounting holes for Cisco AP’s are located in the mounting plate. Standard Cisco mounting brackets
as well as “Bracket 2” can be attached so the “Cisco” logo of the AP is parallel to the hinge. For “Bracket 1” the logo of the AP will be
mounted perpendicular to the hinge. Securely fasten the access point’s mounting plate to the mounting holes on the mounting plate of the
enclosure using four (4) # 8 screws. Attach the Access Point to the mounting plate (Figure 1).





























Page 2















Step 2b
(Any manufacturer’s access points) Install the provided
“T-Bar” bracket by fastening two (2) #8-32 nuts onto the studs at the
bottom of the enclosure. Attach the access point to the T-Bar bracket
using the manufacturer’s instructions for attaching the access point to
a ceiling tile grid (T-Bar). (Figure 2).


















Step 3
(Optional) With the desired number of holes opened, attach
antennas (such as Oberon’s BMANT or DMDUAL) and DAS antennas by
inserting the cables through the door holes. Fasten the antennas to the door
per the antenna manufacturer’s instructions. To retain the water and dust
resistance of the enclosure, antennas should have a gasket to fill the
opening. After installation, connect the RF coax cable from the antenna to
the access point (Figure 3). If using Bulkhead connectors, use Oberon
Bulkhead connectors with provided o-ring (P/N 35-NFBLKHD) to maintain
water tightness.

The assembled unit is now ready for ceiling or wall installation.








Page 3

Advertising