Exhaust Installation—Multiple Manifold Duct

_ _ _ _

_ _ _ _

_ _ _ _

_ _ _ _

_ _ _ _

_ _ _ _

AUTOMATIC ELECTRICAL CONTROL FOR EXHAUST FAN

For one or more dryers to start fan.

Exhaust

Booster Fan

Power Supply

to Fan

Relay Coils

Start and Stop

Switches on

Dryers

For Exhaust Duct less than 14 feet and 2 elbows
equivalent and less than 0.3 inches static pressure.

DRYER EXHAUSTS

Area of section “A-A” must be equal to the sum of dryer exhaust pipes entering
multiple exhaust pipe. (See chart below.)

MODELS: L28FD30, L28US30, L36FD30, L36US30, L36US36, L44FD42

MODELS: L28CD30, L28UR30, L36CD30, L36UR30, L36UR36, L36AR36, L44FD42

MODELS: L44CD42, L50CD42

No. of Dryers
Duct Diameter
(in inches)

(in CM)

No. of Dryers
Duct Diameter
(in inches)

(in CM)

No. of Dryers
Duct Diameter

(in inches)

(in CM)

1

2 3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

6

9 11 12 14 15 16 17 18 19 20 21 22 23 23 24 25 26 26 27 28 28 29 30

15 23 27 30 35 38 41 43 46 48 51 53 56 58 58 61 63 66 66 68 71 71 73 76

1

2 3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

8 12 14 16 18 20 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

20 30 25 41 46 51 56 58 61 66 68 71 73 76 78 81 84 86 89 91 94 97 99 100

1

2 3

4

5

6

7

8

9 10 11 12

12 17 21 24 27 30 32 34 36 38 40 42

30 43 53 61 68 76 81 86 91 97 100 106