Introduction

LED-PAR200B User Manual

6

2010-03-09/15:03

Hanging Clamp

3.

S

ETUP

Power

Warning!

All fixtures must be connected to circuits with a suitable Earth Ground.

To determine the power requirements for a particular fixture, see the label affixed to the back plate

of the fixture or refer to the fixture’s specifications chart.

A fixture’s listed current rating is its average current draw under normal conditions.

All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.

Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.

Po w e r C a b l e C o n f i g u ra t i o n

C

ABLE

P

IN

I

NTERNATIONAL

B

LACK

Live

L

W

HITE

Neutral

N

Y

ELLOW

/G

REEN

Earth

EG (Ground)

Mounting

Orientation

This fixture can be mounted on a truss using a clamp in any

position.

Rigging

The fixture includes a mounting yoke to which 1 rigging clamp can be

bolted.

The hole is 13 mm in diameter.

1. Align the clamp screw with the center hole on the yoke and tighten.

2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.

3. Adjust the angle on the yoke arm as necessary.