Chauvet ZX-30RG User Manual

Page 3

Advertising
background image

Features

Removeable Head -To use the ZX-30RG as a projector, the head may be removed. In order to

remove the head, simply unscrew the four screws holding the head bracket to the body of the unit

and unplug the connecting cable.

Selectable Scanning Range - The ZX-30RG offers the user a choice of 3 scanning ranges (180, 150

or 120 degrees). To select the desired scanning range, simply put the set screw in the hole marked

with the range required.

Function - The ZX-30RG offers the user a choice of either static or scanning. This feature is con-

trolled by the 2 position switch on the bottom of the unit (located just above the fan). This controls

only the scanning mirror. The gobo will always be rotating.

Color - The ZX-30RG comes complete with 4 dichroic glass filters (red, green, yellow and blue). To

insert the filter, unscrew the filter holder on the bottom of the unit and slide the desired color into the

holder. Replace the holder in the unit and screw in tightly.

Gobo - The ZX-30RG is supplied with 4 interchangeable gobos. To change/insert a gobo, remove

the screw on the bottom of the unit securing the gobo holder. Remove the gobo and replace with the

desired gobo. Replace the gobo holder in the ZX-30RG and secure the screw tightly. The ZX-30RG

will accept custom gobos. The gobo has a diameter of 25 mm. The image area has a diameter of

18mm.

Installation / Mounting

Although this unit can be used in an upright position, it is recommended that, for safety purposes,

your lighting effect be properly mounted using a suitable hanging clamp and safety cable. CHAUVET

offers a range of items, which are ideal for safe mounting.

Replacing Lamps

1. Disconnect from main power supply before attempting to replace either lamps or fuse.

2. Ensure that the unit is sufficiently cool, before removing blown lamps.

3. Never touch new lamps with your fingers; use a tissue or a cloth.

In order to replace the lamp, disconnect from main power supply first, and unscrew the lamp

replacement cover, which is highlighted on the diagram (fig.1). Only use the appropriately rated

lamps as use of any other lamp type may cause the unit to be non-operational.

Due to the nature of halogen lamps it is vitally important that you do not touch the new replacement

lamp with your fingers, as this will reduce lamp life considerably. Once again a tissue or cloth can be

used for fitting the replacement lamp.

Finally before using, check that the lamp is housed correctly in the lamp holder and that the lamp

replacement cover has been screwed back into place.

If after replacement of the lamp, the unit is still not working then please contact CHAUVET

for servicing.