Electrical connection – Creda S077EE User Manual

Page 15

Advertising
background image

15

This appliance conforms to the following EEC
Directives:

Low Voltage Equipment
73/23/EEC
93/68/EEC

Electromagnetic Compatibility
89/336/EEC
93/68/EEC

Inner dimensions of the oven:
width

43.5cm

depth

40.0cm

height

32.0cm

Voltage and frequency of power supply:

230-240V~

50Hz

2800-3000W

ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection

heating mode: Convectional

Declared energy consumption for Forced convection Class

heating mode: Fan

Electrical Connection

Electrical connection
The electrical connection to the mains must be made on
the appliance. The power voltage and frequency are as
indicated on the rating plate.
WARNING: THIS APPLIANCE MUST BE EARTHED.

Mounting the power supply cable
To open the terminal board:

Using a screwdriver, press on the tabs situated on each
side of the terminal board cover.

Pull open the terminal board cover.

To mount the power supply cable, proceed as follows:

Unscrew the cable clamp screw and the contact screws
L-N-

6

.

Fasten the wires beneath the screwheads using the follow-
ing colour scheme: Blue (N) Brown (L) Yellow-Green

6

Fasten the power supply cable in the corresponding
cable clamp and close the cover.

Electrical Connection:

Voltage Frequency: 230 V-1+N 50Hz

Fuse Section: 16A
Supply cable: 3x1.5mm

2

You can connect your oven to the system means of a
terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.

Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which is
long enough to allow you to take the oven out of its recess
in the event of maintenance operations (only use HAR - H
05 - RRF quality cables fitted with a plug conforming to
the regulations in force.
The plug must be accessible at all times.

Unplug the appliance before all operations, even when
replacing the oven lamp.

Using the appliance without correct earthing is highly
dangerous.

IMPORTANT:
After connecting the appliance to the flexible cable, tighten
all the screws on the terminal board.

4

2

N

L

Advertising