Cooper Lighting AMETRIX Fixture Doors User Manual

Removing and sealing ametrix fixture doors

Advertising
background image

15

#6-32 x1/2" (12.7mm)

Socket cap allen screw

#6-32 x1/2" (12.7mm)

Socket cap allen screw

2 & 3ft Fixtures

Socket cap allen screw

#6-32 x5/8" (15.8mm)

Socket cap allen screw

#6-32 x1/2" (12.7mm)

#6-32 x5/8" (15.8mm)

Socket cap allen screw

4ft Fixtures

4

1

5

2

3

To Remove Fixture Door

Door Latch

open.

If fixture is indoor, slide door latches to open.

2. If fixture is outdoor, remove screws and slide door latches to

1.

This side

to surface

Repeat sequence tightening all screws to a final 10 inch pounds of torque.

1. Tighten each screw in the order specified above.

2. Using torque Allen driver, and beginning with screw 1, tighten screw to 5 inch pounds of torque.

3. Next, tighten screw 2 to 5 inch pounds of torque.

4. Continue through all screws, following above sequence, tightening each screw to 5 inch pounds of torque.

5.

3. After releasing door, hold door at approximately a

fifteen degree angle and push door away from fixture.

ADY071485 REV A(ECN070344)

Torque Sequence

Screws on outdoor

fixture only

#6-32 x1/2" (12.7mm)

Socket cap allen screw

#6-32 x5/8" (15.8mm)

Socket cap allen screw

#6-32 x1/2" (12.7mm)

Socket cap allen screw

#6-32 x1/2" (12.7mm)

Socket cap allen screw

Socket cap allen screw

#6-32 x1/2" (12.7mm)

#6-32 x5/8" (15.8mm)

Socket cap allen screw

5

1

3

2

4

6

Removing and Sealing Ametrix Fixture Doors

Sheet 1 of 1

mount fixtures vertically.

Supplementary Installation Instructions

Warning

: Before starting any work ensure

that all sources of power are turned off. All

work must meet local/national codes and be

performed by a certified electrician. Do not

Specific details such as fixture and pendant style may differ,

however the mounting configurations are universal.