2.8 Indication Lights
The charger features built in diagnostics. Refer to the table below to interpret the
flashing of the green and yellow indicator lights.

Curtis 1620 Manual

page 6

Flash Pattern

Mode

Charge Status

Yellow on, Green on

Standby Indicator 1

Charge done, ready to use.

Yellow on, Green blinks

1

Charging

Charging normally.

Yellow and Green blink

1

together

Standby Indicator 2

Charge cycle has not started,

refer to troubleshooting section.

Yellow and Green blink alternately

Programming

1311 programmer connected to the unit.

Yellow blinks

1

, Green on

Standby Indicator 3

End of Charge (Veoc) voltage reached.

Charge done, ready to use.(200s delay)

Yellow blinks

1

, Green off

Error

Charge cycle stopped,

refer to troubleshooting section.

Yellow blinks

2

once,

Error

Charge cycle stopped,

2 seconds off, repeats, Green off

refer to troubleshooting section.

Yellow blinks

2

twice,

Error

Charge cycle stopped,

2 seconds off, repeats, Green off

refer to troubleshooting section.

No indicators on

Off/Error

Charger is unplugged, otherwise

refer to troubleshooting section.