Output Power

140 Watts Continuous

Output Voltage

120 Volts +/- 10%

Output Frequency

60 Hz

Output Waveform

Simulated Sine Wave

Input Voltage

10.8 to 15.8 volts

Low Voltage Shutdown

10.5 volt

Problem

Possible Cause

Suggested Solutions

No AC output power
(Power indicator is not
illuminated)

Poor contact with lighter socket

Automotive electrical systems
requires ignition to be on.

Car s lighter socket fuse blown

Over-heating

Vehicle s battery below 10.8
volts.

Ensure the inverter adapter is securely
plugged into vehicle s lighter socket.
Replace the lighter socket if necessary.

Turn the vehicle ignition key to the

Accessory

position.

Check the vehicle fuse panel and replace
the damaged fuse.

Allow inverter to cool down. Ensure that
there is adequate ventilation around the
unit and load is no more than 140 watts for
continuous operation.

Unplug the inverter and charge the vehicle
battery.

Short/Long Beep

Your vehicle s battery input
voltage is below than 10.8 volt.

Vehicle s battery input voltage
is higher than 15.8 volt.

Inverter is overload.

Check vehicle s battery and ensure its
capacity. Change vehicle s battery if
necessary.

Check for your vehicle s battery
manufacturer guideline.

Reduce load to 140 watts max to maintain
regulation.

Contact Screw

Spring

Contact Pin

Fuse

Decorative Ring

Lighter Adapter

CPS140BI contains a fuse inside in the Lighter Adapter (see Figure 2) to protect the unit against
overloading. If the inverter draws more than 140 watts, the internal fuse may be blown to protect
the inverter, vehicle battery and the connected equipment. To replace the fuse, please follow the
instruction below:

1. Unplug the inverter from the power source.
2. Remove the Contact Screw from the Lighter Adapter.
3. Replace the 15 ampere fuse.
4. Reassemble the fuse, contact pin and contact screw carefully.
5. Ensure all pieces showed in Figure 2 are installed in the sequence shown.

*Note: For in-warranty units, the replacement fuse can be obtained from CyberPower

Technical Support. For out-of-warranty units, the replacement 15 ampere fuse can be obtained
from most electronic supply retailers.

WARRANTY RETURN

Cyber Power Systems, Inc.
5555 12th Avenue East, Suite 110, Shakopee, MN 55379, U.S.A.

TEL: (952) 403-9500

FAX: (952) 403-0009

Toll-Free: (877) 297-6937

E-mail:

[email protected]

Web:

www.cyberpowersystems.com

Entire contents copyright

2004 Cyber Power Systems, Inc.

All rights reserved. Reproduction in whole or in part without permission is prohibited

K01-BT14000

C

2004-5-075/back K

Advertising