9. Apply drywall joint compound as needed to finish the cutout. Avoid

covering the four tapped mounting holes.

10. Run the necessary cables for the TPS-6X-DSW and secure them behind the

drywall.

11. When dry, the wall mount docking station can be installed using the four

tapped holes in the PMK-6X-DSW. Refer to the latest revision of the
TPS-6X-DSW Operations and Installation Guide (Doc. 6708) for
installation instructions. Refer also to the comprehensive illustration below.

TPS-6X-DSW Mounting Using MMK-6X-DSW – Exploded View

TPS-6X-DSW

SCREW (4) #06-32 1 1/2"
PAN HEAD (2007254 )

DRYWALL

DRYWALL SCREWS (NOT INCLUDED)
SCREW LENGTH SHOULD NOT
EXCEED DRYWALL THICKNESS BY
MORE THAN 1/2" (13 MM).

PMK-6X-DSW

NOTE: REQUIRED
ADJUSTMENT
PLATES AND
PUSH-ON
FASTENERS NOT
SHOWN.

MUD RING PLATE
(2022809 )

WMKM-6X-DSW Procedure

This section provides the necessary steps for the assembly and installation of the
WMKM-6X-DSW into a wall. Review the procedure and complete the steps in the
order provided. The only tools or materials required and not supplied are a drywall
saw or equivalent, a level, four standard drywall screws, #2 Phillips screwdriver and
tools/material to apply drywall joint compound.