606

EMERGENCY LIGHTS

Architectural

COOPER LIGHTING

(1)

Consult your Cooper Lighting Representative.

(2)

Provision for one meter only.

COOPER LIGHTING - SURE-LITES

®

D I M E N S I O N S

• Dual-voltage input

120/277VAC, 60Hz

• 20 gauge die-formed steel

housing with white powder
coat finish

• Heads match housing

finish

• Knockout, conduit or cord

set

• Supplied with hanger bars,

T-Bar clips

• Single modular electrical

connector

• Remote capability

• Line-latching, Solid-State

voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test
switch/power indicator
light

• UL 924 Listed, Life Safety

NFPA 101, NEC/OSHA,
most state and local codes

D E S C R I P T I O N

The RD Series is a recessed
emergency lighting system
designed for locations where
aesthetics are of utmost
importance. The housing is
fully recessed in dry wall or
grid ceiling installations.
Designer pinchback heads
rotate 358° and swivel 90° to
0°. Ideal for commercial and
institutional environments
where easy recessed
installation and minimal
maintenance are desired.

The RLM Series is a recessed
system packaged in an
attractive flame-resistant
metal housing. It is the unit
of choice for installations
where a recessed product is
desired and the size and cost
of emergency lighting must
be kept to a minimum
without sacrificing
dependability or light output.

RD SERIES

Tw o I n j e c t i o n M o l d e d
T h e r m o p l a s t i c H e a d s

RD1

SLC

6

18

15

10

8

Tungsten Halogen

6

29-12

RD3

SLC

6

27

24

18

14

Tungsten Halogen

12

29-66

RD4

SLC

12

54

-

-

-

Incandescent

9

029-86

RD6

SNC

6

15

12

8

6

Tungsten Halogen

6

29-12

RD7

SNC

6

24

18

12

10

Tungsten Halogen

12

29-66

RLM1

SLC

6

10.8

7.2

-

-

Incandescent

5.4

29-121

RLM2

SLC

6

18

15

10

8

Incandescent

9

29-84

RLM3

SLC

6

27

24

18

14

Incandescent

9

29-84

RLM4

SLC

12

54

-

-

-

Incandescent

9

029-86

RLM8

SNC

6

15

12

8

-

Incandescent

7.2

29-88

RLM9

SNC

6

24

18

12

10

Incandescent

7.2

29-88

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : R D 1 V

5 1/8"

(130mm)

10 1/4" (260mm)

12 7/8" (327mm)

3 1/2"

(89mm)

7" max.

(178mm)

6"

(152mm)

(RD4 Only)

8 1/4"

(210mm)

9 1/4" (235mm)

6 1/4" (159mm)

4 5/8"

(118mm)

Options
(Add as suffix)
A=Ammeter

(2)

SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter

(2)

Alternate Lamps

(1)

Other Options

(1)

Model Number
RD1
RD3
RD4
RD6
RD7
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9

Accessories
(Order separately)
WG2 =Wire Guard
WG7 =Wire Guard
VS=Choose polycarbonate

vandal shield desired
from accessories
sheet

E n e r g y D a t a

Input Current (Max.):

Model No.

120V

277V

RD1, RD3

.12A

.05A

RD4, RLM4

.30A

.13A

RD6

.06A

.03A

RD7

.07A

.04A

RLM1, RLM2, RLM3

.12A

.05A

RLM8

.06A

.03A

RLM9

.07A

.04A

E L E C T R I C A L R A T I N G S

Rated Wattage

to 87 1/2% of rated D.C. Voltage

Lamp Information

Model

Battery

DC Voltage

1 1/2 hours

2 hours

3 hours

4 hours

Type

Wattage

Number

SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery

RLM SERIES

Tw o H i g h - I m p a c t
T h e r m o p l a s t i c H e a d s

R e c e s s e d H o u s i n g

E M E R G E N C Y L I G H T

9 1/4" (235mm)

6 1/4"

(159mm)

12 7/8" (327mm)

10 1/4" (260mm)

9 1/4"

(235mm)

3 1/2"

(89mm)

5 1/8"

(130mm)

8 1/4"

(210mm)

6"

(152mm)

(RLM4 Only)

4 5/8"

(118mm)

Advertising