Continental CX3000 User Manual

Page 2

Advertising
background image

3

2

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . .3

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

CYCLE TIMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

COST OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . .5

SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

CHANGING THE FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6

CHANGING THE UV LAMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

RESETTING THE SERVICE LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . .8

REPLACEMENT FILTERS AND ULTRAVIOLET LAMPS . . . . . . . . . . . . . . . . . .8

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

TYPICAL VERTICAL AND HORIZONTAL INSTALLATION . . . . . . . . . . . . . .10

LIMITED LIFETIME WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

PERFORMANCE DATA AND APPROVALS. . . . . . . . . . . . . . . . . . . . . . . .12

WIRING DIAGRAM . . . . . . . . . . . . . . . . . .. . . . . . . . . . .13

PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

CX3000 EXPLODED VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

IMPORTANT SAFETY INSTRUCTIONS

Before installing the CX3000 purifier, inspect for any signs of damage.
During handling and installation, take care to protect the catalytic hon-
eycomb side
of the product from physical damage, as the aluminum-tita-
nium core is very soft and can be easily damaged.

Warning - Always unplug the power cord from the CX3000 air purifier when
changing the filter or ultraviolet lamps. Never look into a burning ultravi-
olet lamp without proper eye protection as severe damage to the eyes can
result. This product is rated for standard ambient air temperatures during
heating and air-conditioning functions and not rated for elevated air tem-
peratures in excess of 125 degrees fahrenheit.

Do not attempt to clean the catalytic honeycomb core with cleaning
solutions. The catalyst is radiated with short wave ultraviolet light during
periods of non-air flow and is self-cleaning.

Do not install insulation within 76MM or 3 inches of Luminaries.

Access for service is required when mounting above ceilings or behind
walls.

Do not install in a position where the interior module can fall from an
elevated position and cause injury to people or equipment below.

SPECIFICATIONS

Manufacturer:

Continental Fan Manufacturing Inc.

Model:

CX3000

Voltage:

1/120V/60

Dimensions:

21" W x 25" H x 10.25" D

Amps:

0.38

Watts:

44.8

Caution:

Risk of fire - replace only with SP20T10 / 20 watt
UV-C lamps

Fuse:

Replace only with AGC-l fuse

Max Face Velocity:

625 fpm

Max Air Flow:

2170 cfm

UV Range:

254 NM (germicidal)

Weight:

42 LBS

Application:

3000 Sq. Feet

Catalyst:

Titanium Dioxide

Particle Filter:

Electrostatic Needled MERV -11

Service:

UV LAMPS - 1 year
FILTERS - 6 months

Advertising