Rotary ironer RI800-16 Technical data for customer service 04/2005

FAULTS



FAULT

SOURCE


The temperature of the ironing plate does not
correspond with the indicators on the temperature
selectors

1. Thermostat defect – to be replaced
2. Temperature sensor is not close enough

to the ironing plate.


The ironing plate does not heat up

1. The thermostat is on "cold“
2. The rocker switch is set to "0“
3. The electrical connection is interrupted
4. Rocker switch defect – to be replaced
5. Thermostat defect – to be replaced
6. Heating element defect
7. Fuse defect – to be replaced


Does not iron equally along the whole length

1. Check the tension of the ironing plate and

the parallelism with the roll


The pressure of the ironingplate is too low.

1. Check the adjustment of the ironing plate

and the parallelism with the roll

2. Motor for swinging the ironing plate is

defect

3. Microswitch on the pressure arm switches

to soon


During ironing, the roll is too noisy

1. Rollermotor defect
2. Check correct placement of the roller
3. Bearing in the roller defect
4. Gearwheeldrive defect


The roll does not rotate during ironing

1. Check roll and fixation of the roll.
2. Microswitch in footswitch does not function
3. Check the connections on the PCB
4. Check the gearwheeldrive
5. Bearing the roll defect


Ironing plate does not close

1. Microswitch of the fingerguard is defect
2. Finger guard does not lay on the

microswitch in resting position

3. Check the connection on the printed circuit

board