Wing Nut
1/4"-20

Staples

Carriage Bolt

1/4"-20x1/2"

HARDWARE SHOWN ACTUAL SIZE

Carriage Bolt
1/4"-20x1/2"

Bracket

Bell Wire

Lens

Wing Nut
1/4"-20

Wire Clips

Rail

Sensor Wire

Strip wire 7/16"

7/16" (11 mm)

Grey

White

White/Black
Wire

White Wire

Quick-Connect
Terminals

Left Side Panel

Antenna

To release
or insert
wire, push
in tab with
screwdriver tip

SAFETY REVERSING
SENSORS CONNECTIONS

Invisible Light Beam
Protection Area

Safety Reversing Sensor

Cable

Figure 5A

Figure 5B

MOUNTING THE SAFETY SENSORS

Slide a 1/4"-20x1/2" carriage bolt head into the slot on
each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other across
the door. Be sure the lens is not obstructed by a bracket
extension (Figure 5).

Finger tighten the wing nuts.

Recommended Wire Routing

1. Using insulated staples, run the wires from both sensors

to the rail at the door header (Figure 5A).

2. Run the wires through wire clips at the top of the rails.

NOTE: If your access door is near the garage door, you
may choose to install the door control at this time and run
the door control wire along the rail with the sensor wires.

3. Separate the white and white/black wires. Strip 7/16"

(11 mm) of insulation from the end of the sensor wires.
Twist like colored wires together. Connect the bell wire
from safety reversing sensors to the quick-connect
terminals: white wires to the white terminal and
white/black wires to grey terminal (Figure 5B).