Control Pad On The Dehumidifier

Display

Shows the set % humidity level from 35% to 85% or

auto start/stop time (0-24) while setting, then shows

the actual ( +/- 5% accuracy) room % humidity level

in a range of 30%RH (Relative Humidity) to 90%RH

(Relative Humidity).

Error Codes and Protection Code:

AS- Humidity sensor error--Unplug the unit for at least

5 minutes and plug it back in. If error repeats, call for

service.

ES- Temperature sensor error--Unplug the unit for at

least 5 minutes and plug it back in. If error repeats,

call for service.

P2- Bucket is full or bucket is not in the right

position-Empty the bucket and replace it in the right

position. Ensure float switch and foam are secured

properly in bucket.

E1- Unit malfunction--Unplug the unit for at least 5

minutes and plug it back in. If error repeats, call for

service.

EC- Unit malfunction--Please make sure whether the

environment temperature is suitable for the

stated temperature in the manual or not. If not, please

operate the unit under the stated temperature. If the

environment temperature is suitable for the stated

temperature, please call for service.

10

Other Features

Bucket Full Light

Glows when the bucket is ready to be emptied, or

when the bucket is removed or not replaced in the

proper position.

Auto Shut Off

The dehumidifier shuts off after 30 seconds when the

bucket is full, or when the bucket is removed or not

replaced in the proper position. When the humidity

setting is reached, the unit will be shut off

automatically. For some models, the fan motor will

continue operating.

Auto Defrost

When frost builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to

run until the frost disappears. The unit will restart on

its own.

Safety Feature

After the unit has stopped, it cannot resume operation

in the first 3 minutes afterwards. This is to protect the

unit. Operation will automatically start after 3 minutes.

Check Filter Feature

The system starts to log the time once the fan motor

operates. The check filter light will be lit up only when

the accumulated operation time achieves 250 hours

or more. The Reset light (Clean Filter indicator light)

flashes one time per second. After cleaning the air

filter, press the Filter pad and the Reset light (Clean

Auto-Restart

If the unit breaks off unexpectedly due to a loss of

power, it will restart with the previous function setting

automatically when the power resumes.

Setting the Timer

When the unit is on, press the Timer button; the Timer

Off indicator light illuminates. It indicates the Auto Stop

program is initiated. Press it again and the Time On

indicator light illuinates. It indicates the Auto start is

initiated.

Press or hold the UP or DOWN pad to change the

Auto time by 0.5 hour increments. up to 10 hours, then

at 1 hour increments up to 24 hours. The control will

count down the time remaining until start.

The selected time will register for 5 seconds and the

system will automatically revert back to display the

previous humidity setting.

When the Auto start and Auto stop times are set,

within the same program sequence, TIMER ON OFF

indicator lights illuminate identifying both ON and OFF

times are now programmed.

Turning the unit ON or OFF at any time or adjusting

the timer setting to 0.0 will cancel the Auto Start/Stop

function.

When LED display window displays the code of P2,

the Auto Start/Stop function will also be cancelled.