Perfect Aire 1PAMSH36-MZO4-16 User Manual User Manual

Page 15

Advertising
background image

14

CARE AND MAINTENANCE

CASSETTE TYPE

2. Take out the air-in grill (together with the air filter shown

o

in Fig. B). Pull the air-in grill down at 45 angle and lift it
up to take out the grill.

3. Dismantle the air filter
4. Clean the air filter (vacuum cleaner or pure water may

be used to clean the air filter. If the dust accumulation
is too heavy, please use soft brush and mild detergent
to clean it and dry out in a cool place).

Fig. A

Fig.B

1. Open the air-in grill

Push the grill switches towards the middle simultaneously
as indicated in Fig. A. Then pull down the air-in grill.

Cautions:

The control box cables, which are originally

connected with the main body electrical terminals must be

pulled off before doing as indicated above.

DUCT AND CEILING TYPE

2. Take out the air-in grill.
3. Dismantle the air filter
4. Clean the air filter (Vacuum cleaner or pure water may

be used to clean the air filter. If the dust accumulation
is too heavy, please use soft brush and mild detergent
to clean it and dry out in a cool place).

1. Open the air-in grill.

Push the grill switches towards the middle simultaneously
as indicated in following figure sketch. Then pull down the
air-in grill.

Cautions:

The control box cables, which are originally

connected with the main body electrical terminals
must be pulled off before doing as indicated above.

Fig. C

Fig. D

The air-in side should face up when using vacuum
cleaner. (See Fig. C)
The air-in side should face down when using water.
(See Fig. D)

Do not dry out the air filter under direct

Cautions :
sunshine or with fire.

5. Re-install the air filter
6. Install and close the air-in grill in the reverse order of

steps 1 and 2 and connect the control box cables to the
corresponding terminals of the main body.

High-static Pressure Parvis Split Type has no

Note:
air filter.