OPERATION

The following operating features and conditions exist with the switch and magnet units in its
secured condition (positioned, mounted, and wired correctly):
• Triple Biased Switch Operation - The three biased switches will be in the closed position when

the switch is in its secured condition. Opening of the door or removal of the switch unit or mag-
net unit will cause an alarm condition.

• Pry Tamper Operation - The pry tamper switch will be in the closed position when the switch is in

its secured condition (depressed by tamper screw). Removal of the switch unit from the mount-
ing surface will cause a tamper alarm condition.

• Magnetic Tamper Operation - applying an external magnet in an attempt to defeat the switch will

operate a normally closed switch causing a magnetic tamper alarm condition.

WIRING

Warning: A color code wire designation is located on the wire ends. Be sure to label wires
before shortening lead lengths.

If the alarm system provides for a 24-hour supervision circuit, connect the magnetic and pry
tampers to that circuit. This wiring confi guration will signal an alarm condition when the switch unit
is tampered with, whether the door is open or closed. Figure 2a. shows an example of this wiring
confi guration.

If the alarm system does not provide for a 24-hour supervision circuit, connect the magnetic and
pry tampers in series with the switch in the alarm protective circuit. This wiring confi guration will
create an alarm condition when the switch unit is tampered with, but only when the door is closed
in the secure position. Figure 2b. shows an example of this wiring confi guration.

Either confi guration of connecting the HSC supervisory circuits complies with Underwriters' Labora-
tories UL 681 installation standards.

WIRING DIAGRAM: Figure 1.

HSC-1

NOTE: ALL CIRCUITS SHOWN WITH MAGNET AND SWITCH ASSEMBLIES IN SECURED CONDITION.

DWG# 1057-6

HSC-1 WIRING CONNECTION TO THE EVD-M AND EVD-1

(POTTER ELECTRONIC VIBRATION DETECTOR SYSTEM MODELS)

Figure 2a.

TAMPERS

MODEL EVD-M/EVD-1

CONTROL UNIT END OF LINE RESISTORS

ALARM

PROTECTIVE ZONE

+

-

HSC-1

DRAIN WIRE FOR OUTER SHIELD

DRAIN WIRE
FOR INNER
SHIELD

HIGH SECURITY CABLE

24 HOUR

ALARM

ZONE

RECOMMENDED CONNEC-

TIONS

Figure 2b.

ALTERNATE

SERIES

CONNECTIONS

HSC-1

TAMPERS

MODEL EVD-M/EVD-1

CONTROL UNIT END OF LINE RESISTORS

ALARM

PROTECTIVE ZONE

+

-

DRAIN WIRE FOR OUTER SHIELD

DRAIN WIRE
FOR INNER
SHIELD

HIGH SECURITY CABLE

NOTE: The green wire is not used,
insulate the loose end.

NOTE: The green wire is not used,
insulate the loose end.