Features – Progressive Industries EMS-PT30C User Manual

Page 2

Advertising
background image

Features

High/Low Voltage Protection

Whenever AC power falls below 104 volts, or rises above 132 volts, the EMS

automatically shuts down power to the RV. The EMS will monitor the power and once

the AC power rises above 104 volts, or drops below the 132 volt level, the time delay

indicator flashes for the preset time and then automatically restores power to the RV.

Time Delay for A/C Compressor

If AC power is interrupted, or the EMS detects a fault condition, the built in time

delay is activated. There is a 136-second (02:16) time delay.

3-Mode Surge Protection

This feature provides full surge protection L-N, L-G, and N-G. Total Joule rating is

1790, 44,000A Surge Current. Response time of <1 nano second.

Surge Indicator

In the event of a power surge and the surge protector circuit is damaged within the

EMS, L-N, or L-G, the digital display error code will read E-10. This indicates the

EMS needs to be serviced.

Reverse Polarity Protection

If AC power is a reverse polarity condition, the EMS will not allow power to the RV

and the error code will read E1.

Open Neutral Protection

If AC power has an open neutral condition, the display will not light, and the EMS

will not allow power to the RV.

Open Ground Protection

If AC power has an open ground condition, the EMS will read an error code of E2,

and will not allow power to the RV.

AC Frequency Protection

If AC power frequency deviates plus/minus 9 hertz from 60 cycles per second, the

EMS will shut down AC power. An Error Code of E7 will be displayed when the

frequency is high; and an Error Code of E8 will be displayed when frequency is low.

Accidental 240V Protection

If 240 volts is detected when plugging into AC power, the EMS will NOT allow

power to the RV. If this condition occurs while power is applied to the RV, the EMS

shuts off power instantly. The display will read the voltage and E-3 for the error.
(NEVER BYPASS THE EMS WHEN THIS OCCURS.)

Display

Continuously scrolls all of the AC power information, including voltage, current,

frequency, error codes, and previous errors. Each reading is displayed for two (2)

seconds.

Previous Error Code

This feature tells the user what the previous error was and why power was interrupted

to the RV. To read a Previous Error Code, put a “P” in front of the “E” code. This is

only displayed if an actual error occurs. The error is deleted when the power is

disconnected from the EMS.

Weather Resistant

Can be exposed to elements, however, may not be submerged.

Microprocessor controlled

The computer is driven by a state-of-the-art microprocessor that is programmed with

software to drive the entire EMS.

Built-in Lock Bracket

Allows the user to secure the EMS to power source to prevent theft.

Advertising