Normal operating sequence 4.0 – Proheat A4 User Manual

Page 33

Advertising
background image

PROHEAT AIR A2/A4 INSTALLATION MANUAL

4-1

Switch "ON"

After powering up the heater, prime the fuel pump and set the DCP

(Temperature Sensor and Heating Mode) the heater is ready to start. Pushing

the HEAT button, the heater goes to "Precheck".

Precheck

The motor runs for 10 seconds and the DCP performs a short diagnostic

cycle, checking components for proper ranges, short circuit and open circuits.

If there are no errors the heater goes to “ignition”.

Ignition

Ignition is indicated by the flashing heat symbol on the display of the DCP.

The heater starts to glow for 30 seconds. The fuel pump starts, and the glow

plug illuminates. 2 seconds after the glowing time, the motor starts in full

speed. Once the flame sensor reaches the required temperature, the heater

switches off the glow plug and enters into “full output”. If the start is not

successful the heater will attempt to restart one more time.

Full Output

The heat symbol stops flashing and the heater enters the demanded heating

mode. Once the temperature sensor reaches 120°C (248°F) at the heater,

the heater shuts the fuel pump off and goes to “Purge”.

Purge

Purge is indicated by a flashing FAN symbol on the display of the DCP. The fuel

pump shuts off immediately. The blower motor continues to run for 6 minutes

to cool down the combustion chamber. After 6 minutes the DCP checks the

air temperature at the heater. If the temperature is above 140°F (60°C), the

blower will run for 6 more minutes. When the temperature is below 140°F

(60°C) the motor will shut OFF. The heater will now enter Standby.

Standby

The heater continues checking the ambient temperature using the pre-

selected temperature sensor. Once the temperature drops below the preset

temperature, the heater will re-enter “Precheck” and repeat steps 2 to 6. The

heater will continue to repeat these steps until it is switched “OFF.”

Inspect the installation again for leaks.

TO ENSURE FULL WARRANTY COVERAGE COMPLETE THE WARRANTY CARD

AND MAIL TO SEASTAR SOLUTIONS.

4.0.1

4.0.3

4.0.5

4.0.4

4.0.2

4.0.6

NORMAL OPERATING
SEQUENCE

4.0

NOTICE

In Precheck and Ignition modes the heat

symbol will be flashing on the DCP.

NOTICE

To increase the heating demands, use

the left (decrease) and right (increase)

buttons.

NOTICE

After 6 minutes cool down, turn OFF

the heater and reset the menu number

5 (ME 5), for customer applications.

Advertising
This manual is related to the following products:

A2