Installation hood on the wall – PYRAMIDA GH 20-60 slim v.1 User Manual

Page 32

Advertising
background image

EN

32

Hoods Pyramida WH 10-50, WH 20-60,

WH 22-60, GH 20-60 slim are for the mode
of ventilation or recirculation.

Air outlet in the mode of ventilation in the

housing hood are two circular holes (A and
B), which closed caps. You must select one
of the holes, lift the cover and cut or break off
brackets (Fig. 1).

Inserted into the opened hole adapter

supplied (Fig. 2).

Typically, the air exhaust is used pile hole A.

This selection from the vents, make sure that
the other remains closed flap.

Attach the hood by screws with plugs

from the installation kit the rear surface of
the wall (Fig. 3) or the upper surface of the
cupboard. Connect ductwork with adapter
of hood (Fig. 4).

Bring out the other end of the ductwork

in ventilation shaft. Make sure there are no
gaps in the joints.

instAllAtion Hood on tHe WAll

Fig. 1

Fig. 2

Fig. 3

Fig. 4

А

Б

Advertising