Setup, Assembly, Mounting – Crestron electronic Pre-Construction Wall Mount Back Box BB-6X-DSW User Manual

Page 9

Advertising
background image

Crestron BB-6X-DSW

Pre-Construction Wall Mount Back Box

Setup

Assembly

Required Tools:

• #2 Phillips tip screwdriver

The back box mounting enclosure comes fully assembled except for a grounding
screw. To prepare for mounting, complete the following procedure:

1. Remove knockouts as required.

2. Attach the supplied #08-8B self-tapping screw to back box mounting

enclosure assembly for grounding.

NOTE: The #08-8B self-tapping screw (2007277), supplied for grounding
purposes, is installed in the rear of the back box mounting enclosure assembly.

Mounting

Required Tools and Materials:

• #2 Phillips tip screwdriver
• Level
• Standard drywall screws or nails (not included)

CAUTION: Allow an air gap of a least 12 inches (30.48 cm) in the wall cavity
above and below the TPS-6X-DSW for heat dissipation.

NOTE: If your installation is not on wooden studs, be sure to consider the needs of
your particular situation. For example, screw type may vary for steel studs, etc.

To mount the back box, complete the following procedure (refer to illustration on the
following page).

1. Position the back box against the stud so the extended edge of the attached

mounting plate covers the front edge of the stud. Be sure the side of the
back box is also against the side of the stud.

2. Use the level and verify the back box is horizontal. Leveling must be done

before proceeding.

3. Attach the back box to the left or right side of the stud with standard

drywall screws or nails (not included). If mounting to the left side of a stud,
the back box must be turned over so the extended edge of the attached
mounting plate is on the right side.

4. Feed cables through the knockout holes.

NOTE: This assembly should use Class 2 wiring only.

Installation Guide – DOC. 6728A

Pre-Construction Wall Mount Back Box: BB-6X-DSW

5

Advertising