REPROGRAMMING

There are 5 charge profiles, and 5 programming adjustments that
can be made to the profiles.

The profiles are:

F1 is a single stage float profile generally used for gel and starting
type batteries. There are no adjustments available to this profile.

F2 is a two stage profile for deep cycle wet cell batteries. Bulk
charging, a gassing cycle, then termination.

F3 is a three stage profile for deep cycle wet cell batteries. Bulk
charging, a gassing cycle, and maintenance.

F4 is a three stage profile for AGM batteries. Bulk charging,
absorption cycle, and maintenance.

F5 is for Lithium ion batteries and must be pre-programmed at the
factory.

The adjustments are:

d0 standard gassing/absorption cycle. Applicable to most
applications

d1 shortened gassing/absorption cycle. For frequent shallow
discharging, or frequent recharging of batteries with very little
discharge. Suitable for opportunity charging.

d2 lengthened gassing/absorption cycle. For batteries requiring
long gassing/absorption cycles. US Battery, and Full River are
two brands that benefit from longer charge cycles.

r0 when set to the F2 profile, charge will terminate, and will not
monitor the battery.