Reznor RBL (Cabinet Blower) Unit Installation Manual User Manual

Installation / operation, 0 general, 1 hazard labels and notices

Advertising
background image

Form I-RBL, P/N163219R2, Page 1

Form I-RBL (Version A)

Obsoletes Form I-RBL/RBA/RBHA

Applies to: Blower Cabinet Model RBL

INSTALLATION / OPERATION

AG

EN

CY

PROCE

SS

ST

A

R

T-

U

P

PR

ODUCT

C

U

ST

O

M

ER

WAR

RA

NT

Y

CO

NVERGENT

QU

ALITY SYSTE

M

CQS

CQS

Model RBL,

Indoor/Outdoor

Blower Cabinet,

5000 - 15000 CFM

1.0 General

1.1 Hazard Labels and Notices

There are warning labels on the blower cabinet and throughout this manual. For your

safety, read the definitions below and comply with all boxes labeled

CAUTION, WARN-

ING, and DANGER during installation, operation, maintenance, and service of this unit.

Definitions of Hazard Intensity Labels in this Manual

HAZARD INTENSITY LEVELS of Warnings in this Manual

1. DANGER: Failure to comply will result in severe personal injury or death

and/or property damage.

2. WARNING: Failure to comply could result in severe personal injury or death

and/or property damage.

3. CAUTION: Failure to comply could result in minor personal injury and/or

property damage.

WARNING: Improper installation, adjustment, alteration, service,

or maintenance can cause property damage, injury or death.

Read the installation, operation, and maintenance instructions

thoroughly before installing or servicing this equipment.

1.0 General .......................................................................1-2

1.1 Hazard Labels and Notices ........................................ 1

1.2 General Information .................................................... 1

1.3 Warranty ....................................................................... 2

2.0 Uncrating ....................................................................... 2

3.0 Dimensions ................................................................... 2

4.0 Suspending and Mounting ........................................2-4

5.0 Mechanical ...............................................................4-10

5.1 Unit Inlet Air ................................................................. 4

5.2 Duct Connections ....................................................... 8

5.3 Blowers, Belts and Drives .......................................... 9

5.3 Blowers, Belts, and Drives (cont'd) ......................... 10

6.0 Electrical Supply and Connections...................... 10-11

7.0 Commissioning and Start-Up .................................... 11

INDEX ................................................................................. 12

INSTALLATION RECORD ................................................. 12

Table of Contents

1.2 General Information

A Model RBL blower cabinet is engineered for use with Reznor

®

duct furnaces when

design considerations do not permit the use of a packaged system. The cabinet is

weatherized with an integral curb cap base for outdoor installation, but may also be

installed indoors. The blower cabinet has standard horizontal inlet and outlet air open-

ings equipped with duct flanges and may have an optional bottom air inlet. Model RBL

is available with a downturn plenum which provides a bottom outlet for supply air.
This booklet includes installation and operation information. Installation should be

done by a qualified agency in accordance with the instructions in this manual and in

compliance with all codes and requirements of authorities having jurisdiction. Before

beginning installation, review the instructions in this booklet and become familiar with

the required procedures.