Appendix (cont’d) – Reznor REC (Evaporative Cooling) Unit Installation Manual User Manual

Page 12

Advertising
background image

Form I-REC, P/N 16021R3, Page 12

Appendix (cont’d)

REC

CFM

Pressure Drop

REC

CFM

Pressure Drop

REC

CFM

Pressure Drop

REC

CFM

Pressure Drop

12” Media

Moisture

Elimination

Pad*

12”

Media

Moisture

Elimination

Pad*

12”

Media

Moisture

Elimination

Pad*

12” Media

Moisture

Elimination

Pad*

40

575

0.02

N/A

60

1550

0.06

N/A

80

2750

0.1

0.06

180

3100

0.02

0.01

1000

0.06

N/A

2000

0.08

0.05

3500

0.16

0.09

4000

0.04

0.02

1500

0.12

N/A

2500

0.14

0.08

4000

0.2

0.12

5000

0.06

0.04

2000

0.2

0.11

3000

0.2

0.12

4500

0.26

0.15

6000

0.08

0.05

2500

0.32

0.17

3500

0.26

0.16

5000

0.32

0.19

7000

0.1

0.07

3000

0.44

0.25

4000

0.36

0.21

5500

0.38

0.23

8000

0.14

0.1

3500

0.6

0.34

4500

0.46

0.27

6000

0.44

0.27

9000

0.18

0.12

4000

0.8

0.44

5000

0.56

0.33

6500

0.52

0.32

10000

0.22

0.15

50

1175

0.04

N/A

5500

0.68

0.4

7000

0.62

0.37

11000

0.26

0.18

1500

0.08

N/A

5800

0.74

0.48

7500

0.7

0.42

12000

0.3

0.21

2000

0.12

0.08

70

1950

0.06

0.04

8000

0.8

0.48

13000

0.36

0.25

2500

0.2

0.12

2500

0.1

0.06

90

3100

0.1

0.05

14000

0.42

0.29

3000

0.28

0.17

3000

0.14

0.09

3500

0.12

0.07

15000

0.5

0.33

3500

0.4

0.24

3500

0.2

0.12

4000

0.16

0.1

16000

0.56

0.38

4000

0.52

0.31

4000

0.26

0.18

4500

0.2

0.12

17000

0.64

0.43

4500

0.64

0.39

4500

0.36

0.2

5000

0.24

0.15

18000

0.72

0.48

5000

0.8

0.48

5000

0.4

0.25

5500

0.3

0.18

5500

0.5

0.3

6000

0.36

0.21

6000

0.58

0.35

6500

0.42

0.25

6500

0.68

0.41

7000

0.48

0.29

7000

0.8

0.48

7500

0.56

0.33

8000

0.64

0.38

8500

0.72

0.43

8800

0.76

0.48

Pressure Drop Table - REC Sizes 40 - 180

* Moisture elimination catch pad (Option ASA1) is required above 600 FPM.

600 FPM = REC 40 w/2600 CFM; 50 w/3200 CFM; 60 w/3700; 70 w/4500 CFM;

80 w/5200 CFM; 90 w/5600 CFM; and 180 w/11200 CFM.

www.ReznorHVAC.com; (800) 695-1901

©2014 Reznor, LLC. All rights reserved.

Trademark Note: Reznor

®

is registered in the United States and other countries.

All other trademarks are the property of their respective owners.
0514 Form I-REC (Version A.1)

Installer:
Name ____________________________________________________

Company

____________________________________________________

Address ____________________________________________________

____________________________________________________

____________________________________________________

Phone

_________________________________

Distributor (company from which the unit was purchased):

Company ____________________________________________________

Contact

____________________________________________________

Address ____________________________________________________

____________________________________________________

____________________________________________________

Phone

_________________________________

Model __________ Serial No._____________________Date of Installation _____________

INSTALLATION

RECORD - to be

completed by the

installer:

Index

A

Adjust Water Flow Over Media 8

Airflow Direction 5

AquaSaver timed metering controls 5

AquaSaver Timed Metering System 6

AquaSaver Timer Adjustment 9

AquaSaver Water Flow Adjustment 8

B

Ball Valve 8

Base 3

Bleed Line Connection 6

Bleed Line Fitting 6

C

Cross-Reference Application Chart 11

D

Dimensions 3

Dimensions - Model REC 360 11

Distributor 12

Drain 6

E

Electrical Connections 7, 8

F

Fill & Drain Kit (Opts CT1, CT2, CT3) 7

Filling and Adjusting 7

Float and Pump Control System 8

Float & recirculating pump controls 5

Float Valve 6

Freeze Protection (Option CT5) 7

G

General 2

I

Inlet Water 6

INSTALLATION RECORD 12

Installer 12

J

Junction Box 10

L

Leg Height 4

Legs 3

M

Maintenance 9

Media 9

Microprocessor Control 6, 9

Model 12

Moisture Elimination Pad 4, 5

O

Overflow Connections 6

P

Preparation Check List 2

Pressure Drop Table 12

Pump and Float Controls 6

Pump & Float System, Option ECD2 8

Pump/junction box assembly 5

R

Replacing Evaporative Cooling Media

Pads 10

Re-position Pump Assembly 5

S

Serial No. 12

T

Timed Metering Control System 6, 8

Timed Metering Control System, Option

ECD1 8

Timer Adjustment 9

Transition Duct 3, 4

Troubleshooting Chart 11

V

Drain (2-Way Valve) 7

Supply (3-Way Valve) 7

W

Warranty 2

Water Connections 5

Water Feed Line 10

Water Leaks 7

Water Level 7

Water Pump 10

Weight 2

Wiring Diagrams 8

Advertising