Form I-UD&APD Series-CS (11-14), PN 197096R1, Page 1

APPLIES TO:

Standard Power Vent Unit Heaters:

Models UDAP and ADP Sizes 30, 45, 60, 75, 100, 125

Separated Combustion Unit Heaters:

Models UDAS Sizes 30, 45, 60, 75, 100, 125

FORM I-UD&APD Series-CS (11-14)

Obsoletes Installation Form RZ-NA- I-UD-CS

Ceiling Suspension Kit,

Option CK22

Description/

Application

1) Along the front edge of the top of the heater cabinet, find three sheet-

metal screws. Remove all three and keep.

2) Position a suspension angle along the top edge of the cabinet as illus-

trated, lining it up with four holes. Using the three screws removed in

Step 1 and the one screw in the kit, attach the suspension angle to the

top of the heater.

Installation

Instructions

This kit includes a set of suspension angles that will allow the installer to

attach the heater directly to the ceiling without the use of hanger rods. The

suspension angles are designed to provide the required clearance above the

heater. These suspension angles may be used on Power Vented & Separated

Combustion Fan Type Model Sizes 30, 45, 60, 75, 100, and 125.

Each Option Package CK22,

P/N 197094, includes:

WARNING: Improper installation, adjustment, alteration, service

or maintenance can cause property damage, injury, or death. Read

the installation, operation and maintenance instructions thoroughly

before installing or servicing this equipment.

Installation should be done by a qualified agency in accordance with the

instructions on this sheet and in compliance with all codes and requirements of

authorities having jurisdiction. Suspension of the heater is the responsibility of

the installer.
Before suspending the heater, check the supporting structure to be used to verify

that it has sufficient load-carrying capacity to support the weight of the unit.

Refer to the

illustration in

Figure 1, page 2.

Qty

P/N

Description

Model

2

1000050

Suspension Angles

APD

2

195496

Suspension Angles

UDAP

1

195638

Sheetmetal Screw

All

Weight - Standard Power Vent, Fan Type Unit Heater

Size

30

45

60

75

100

125

Weight (lbs)

54

59

67

72

96

101

Weight (kg)

24

27

30

33

44

46

Weight - Separated Combustion, Fan Type Unit Heater

Size

30

45

60

75

100

125

Weight (lbs)

54

59

67

72

96

101

Weight (kg)

24

27

30

33

44

46