APPLIES TO:

Hanger Kit Options CK3,

CK7, CK8, CK9, CK10, CK19

HAZARD INTENSITY LEVELS

1. DANGER: Failure to comply will result in severe

personal injury or death and/or property damage.

2. WARNING: Failure to comply could result in severe

personal injury or death and/or property damage.

3. CAUTION: Failure to comply could result in minor

personal injury and/or property damage.

Description/Application/Table of Contents

Description, parts listing, and illustrated instructions are provided for each hanger kit. These kits are designed

only for the models and applications described below.

See the referenced heater installation manual for clear-

ances (top, sides, bottom, front, and rear), suspension dimensions, and weights. Suspension of the heater is the

responsibility of the installer.

WARNING: The instructions in this sheet are written for adding new suspension points or

preparing a heater for suspension prior to installation. If your heater is installed, for your

safety, turn off the gas and the electric before adding or changing suspension. Follow the

instructions on the heater to restart. Check for proper operation.

Other

Ce iling Bracket for Unit Heaters - Option CK22 is available for small sizes of Models UDAP and UDAS.

Hanger See Supplemental Installation Form RZ-NA I-UD-CS.

Kits

Infrared Models - Options CK11-CK18 are not included in this form. Options CK11-CK18 are hanging chain and

turnbuckle kits for tubular infrared heaters. For parts lists and instructions for hanger and turnbuckle kits, see Supple-

mental Installation Form RZ-NA I-VR-HK and/or RZ-NA I-VR/TRP/TR-TK. Hanging chain for infrared high intensity

heaters is Option UE1 or UE2. See Heater Installation Manual, Form RZ-NA I-RIH.

Option

Kit

Description

Use with

Models

Application

Page

Reference Heater Installation Manual

by Model

CK3

Swivel Connections
for 1" Pipe for 4-pt
Suspension

(H)EEDU Duct
Furnace

To adapt the duct furnace so that it may be
suspended from threaded 1" stationary
pipes.

2

EEDU and HEEDU - Form RZ-NA I-
EEDU

CK7

4-pt Suspension
Conversion

F

To add two hanger brackets for changing

from standard 2-pt suspension to 4-pt
suspension.

2-3 F - Form RZ-NA I-F/B

3-4 UDAP and UDAS - Form RZ-NA I-

UDA
F - Form RZ-NA I-F/B

CK9

4-pt Suspension
Conversion Plus
Swivel Connections

F

To add two hanger brackets to change from

standard 2-pt suspension to 4-pt
suspension and adapt the unit so that it
may be suspended from four threaded 1"
stationary pipes.

4

F - Form RZ-NA I-F/B

5-6 LDAP - Form RZ-NA I-LDAP

UDAP and UDAS - Form RZ-NA I-
UDA
UDBP and UDBS - Form RZ-NA I-
UDB
B and F - Form RZ-NA I-F/B
OH and OB - Form RZ-NA I-OH/OB
RA and RAD - Form RZ-NA I-
RA/RAD 140/235
RA and RAD - Form RZ-NA I-
RA/RAD 350/500

CK19

Alternate Suspension
Points providing
nearly equal loading
at four points

B

Suitable for units equipped with isolation

vibration suspension and or seismic pro-
tection with longer than 10" rod hangers.
Option CK19 changes the suspension
points and suspension dimensions.

7-8 B - Form RZ-NA I-F/B

CK8

Swivel Connections
for 2" pipe for 2-pt
Suspension

UDAP; UDAS; F To adapt a unit with 2-pt suspension so

that it may also be suspended from two
threaded stationary pipes.

CK10

Swivel Connectors
for 1" Pipe for 4-pt
Suspension

LDAP Packaged
Heaters; UDAP;
UDAS; UDBP;
UDBS; B; OH;
OB; RA; RAD;
and F with
optional 4-pt
suspension

To adapt a unit with 4-pt suspension so
that it may be suspended from four
threaded 1" stationary pipes.

Advertising