Reznor X Option - Option - Installation - Power Venter User Manual

Description/ application, Components, Products only

Advertising
background image

Form I-X Venter, P/N 136958R1, Page 1

1. DANGER: Failure to comply will result in severe personal injury or death

and/or property damage.

2. WARNING: Failure to comply could result in severe personal injury or

death and/or property damage.

3. CAUTION: Failure to comply could result in minor personal injury and/or

property damage.

Installation, Operation, and Parts for Power Venter,

Options CA1, CA2, CA3, and CA4

Form I-X Venter (Version A)

Obsoletes Form I-X/XE Venter

Applies to

:

Model X Duct Furnace plus

Obsolete Models (H)CX, DX,

(H)XE, (H)CXE, (C)XL, and (C)XLB

WARNING

Improper installation, adjustment, alteration, service, or maintenance can cause property

damage, injury or death. Read the installation, operation, and maintenance instructions

thoroughly before installing or servicing this equipment.

Description/

Application

WARNING

Optional power venter and venter flue adapter are designed for

USE WITH THESE DESIGNATED REZNOR

®

PRODUCTS ONLY.

DO NOT install these power venters on any other Reznor

®

equipment

including Reznor

®

Model F and Model B gravity-vented unit heaters. Use only

the power venting kits that are especially designed for F and B Models.

DO NOT install these venters on equipment not manufactured with the

Reznor

®

brand.

*Models with prefix "H" are not listed separately throughout this form. Information for corresponding

"standard" model applies to the "H" model.

** Power venter cannot be installed on XLB/CXLB Sizes 30-105 when equipped with an optional blower

cabinet.

The Option CA power venter is a motorized vent exhauster designed to permit the

installation of a gravity-vented heater in an area of negative pressure up to 0.15" w.c.

or where horizontal venting is required. The venter assembly in this instruction form is

designed for and may

only be installed on the Reznor equipment listed below.

Use with Reznor

®

Models Description

X/DX/HX*; CX/HCX*

Duct Furnace

XE/HXE*; CXE/HCXE*

Packaged Duct Furnace & Blower

XL/CXL; XLB/CXLB**

Fan & Blower Type Unit Heaters

HAZARD INTENSITY

LEVELS used in these

instructions

Components

Option packages are listed for currently manufactured Model X duct furnaces. Obso-

leted models are also listed where applicable. Review carefully and verify that the parts

are correct for the heater being serviced.

Packages Apply to Models X/DX

1

/CX

2

/XE/CXE

2

75

100

125

150-175

200-225

250-300

1

350

2

-400

Package P/N's by Option

CA Designation and

Voltage for Models

X/DX/CX/XE/CXE

Option CA1-115V

136959 136960 136961 136962

136963

136964

136965

Option CA2-208V

136966 136967 136968 136969

136970

136971

136972

Option CA3-230V

136973 136974 136975 136976

136977

136978

136979

Option CA4-460V

136980 136981 136982 136983

136984

136985

136986

Components

In Option(s)

Component P/N's

Venter Sub Assembly

CA1

29992

29994

CA2

30229

30233

CA3

30231

30235

CA4

29992

29994

Transformer .25KVA

CA4 only

11279 (460 to 115)

Venter Flue Adapter

All (CA1,2,3,4)

14516

6536

6539

6542

12730

12731

12732

2

1

For Model DX300, select package for Model X400.

2

Package P/N's listed

do not apply to Model CX350 or Model CXE350. These

models require the same components as listed for a Size 350

except the venter flue adapter is different. Venter Flue Adapter

required is

P/N 46163.

®