Reznor CAUA Option - Installation - Vent/Combustion Air Kits User Manual

Description and application

Advertising
background image

Form I-OPT-VC, Mfg #205892, Rev 8, Page 1

Description

and

Application

Installation of Horizontal (Option CC6) and

Vertical (Option CC2) Vent/Combustion Air Kits

for Reznor

®

Separated-Combustion Systems

Form I-OPT-VC (Version F.2)

Obsoletes Form I-OPT-VC (Version F.1)

These vent/combustion air kits are designed to be used when installing the Reznor

separated-combustion equipment listed in the table.

Follow the instructions in

the heater installation manual or venting manual shipped with the heater. The

kits identified as Option CC2 (vertical) and Option CC6 (horizontal) are the only

vent/combustion air systems approved for the models listed. Do not use these kits

with any other products.

INSTALLATION WARNING: This vent/combustion air kit must be installed according

to the instructions provided with the heater. If these instructions are not available,

contact your distributor to obtain the installation form listed in the Table above. The

qualified agency performing this work assumes responsibility for this installation.

APPLICATION WARNING: Separated combustion units are not designed or approved for use

in atmospheres containing flammable vapors or atmospheres heavily laden with chlorinated

vapors.

®

Application of Vent/Combustion Air Kit by Reznor

®

Model

Follow Instructions in the latest

version of the Heater Installation

or Venting Installation Manual:

Model

Description

Application

AHCA or

AHDA with SC

Furnace

Packaged Air Conditioning Split
System with Optional Furnace(s)

These models

MUST be

installed as a separated-

combustion system

and always

REQUIRE

installation of

a Reznor®

vent/combustion air kit,

Option CC2 or Option CC6.

Models SSCBL, SSCDBL,

AHCA, and AHDA with more

than one furnace section

require a vent/combustion

air kit for each furnace

section.

Form I-AH-GF

HSC

Duct Furnace (High CFM)

Form I-SC

SC

Duct Furnace (Std CFM)

SCE

Single Furnace Packaged System

Form I-SCE

SDH

Single Furnace Packaged System

Form I-SDH-V

SFT

Fan-Type Unit Heater

Form 432

SHH

High Efficiency Packaged System

Form I-SHH-V

SSCBL

1, 2, or 3 Furnace Packaged System

Form I-SSCBL

SSCDBL

2 or 4 Furnace Packaged System

UDAS

Fan-Type Unit Heater

Form I-UD-V-SC

UDBS

Blower-Type Unit Heater

UEAS

High Efficiency Unit Heater

Form I-UEAS

CAUA

Vertical (Upflow) Packaged System

IF installed as a separated-
combustion system, Option

CC2 or CC6 is

required.

Form I-CAUA

Verify parts and follow the instructions in the heater or

venting installation manual shipped with the heater.

(For a "generic" packing list of components, see page 2.)

Applies to:

All Models Listed in Application Table

Advertising