• Electrical connections must be in compliance with

all applicable local codes and ordinances, and with
the current revision of the National Electric Code

(ANSI/NFPA 70).

• For Canadian installations the electrical connections

and grounding shall comply with the current Canadian
Electrical Code (CSA C22.1 and/or local codes).

Pre-Electrical Checklist

Verify the voltage, frequency, and phase of the supply

source match the specifications on the unit rating plate.

Verify that the service provided by the utility is sufficient

to handle the additional load imposed by this equipment.
See Table 2 (page 11) or the unit wiring label for proper
high and low voltage wiring.

Condensate Drain

Figure 5. Condensate Drain Location

Figure 4. Roof Top Installation

Horizontal to Downflow Conversion

The unit is shipped ready for horizontal duct connections.
If down flow ducts are required, the unit must be converted
following the steps below for both the supply and return
ducts.
1. Remove both horizontal duct caps.
2. Locate the duct cap inside the duct openings and remove

the screw holding it in place.

3. Lift the cap out of the unit. (

Hint:

The cap can be pushed

up from the bottom by reaching through the fork slot).

4. Cover the horizontal duct openings with the horizontal

duct caps. The insulation will be on the indoor side.

5. Fasten the cover with screws to seal.

Condensate Drain

Condensate is removed from the unit through the 3/4”
female pipe fitting (Figure 5) located on the front side of
the unit. Install a 2 inch condensate trap in the drain line of
the same size and prime with water. When connecting rigid
drain line, hold the female fitting with a wrench to prevent
twisting.

Do not over tighten!

Refer to local codes and

restrictions for proper condensate disposal requirements.

ELECTRICAL SHOCK, FIRE OR EXPLOSION

HAZARD

Failure to follow safety warnings exactly could

result in serious injury or property damage.
Improper servicing could result in dangerous

operation, serious injury, death or property

damage.
• before servicing, disconnect all electrical

power to furnace.

• When servicing controls, label all wires prior

to disconnecting. Reconnect wires correctly.

• Verify proper operation after servicing.”

WARNING:

RISQUE DE CHOC ÉLECTRIQUE, D’INCENDIE

OU D’EXPLOSION

Le non-respect des avertissements de sécurité

pourrait entraîner un fonctionnement dangereux

de l’appareil, des blessures graves, la mort ou

des dommages matériels.
Un entretein incorrect pourrait entraîner un

fonctionnement dangereux de l’appareil, des

blessures graves, la mort ou des dommages

matériels
• Couper toute alimentation électrique au

générateur d’air chaud avant de prodéder

aux travaux d’entretein.

• Au moment de l’entretien des commandes,

étiquetez tous les fils avant de les

débrancher. S’assurer de les raccorder

correctement.

• S’assurer que l’appareil fonctionne

adéquatement aprés l’entretien.

AVERTISSEMENT:

ELECTRICAL WIRING

Advertising
This manual is related to the following products: