Installation Instructions

Downfl ow Adaptor

INTRODUCTION

The downfl ow adaptor kit is designed to support the indoor coil of our air handler in a downfl ow installation.
NOTE: This kit must be installed before the air handler is mounted in the downfl ow confi guration.

These instructions are primarily intended to assist qualifi ed individuals experienced in the proper installation of this
appliance. Some local codes require licensed installation/service personnel for this type of equipment. Read all
instructions carefully before starting the installation.

Figure 1. Location of Major Components

INSTALLATION SEQUENCE

WARNING:

To avoid risk of electrical shock, personal in-
jury, or death, disconnect electrical power to
the unit before performing any maintenance
or service. The unit may have more than one
electric power supply.

NOTE: For A cabinet size air handlers in the downfl ow
position, it is recommended that the fi lter rack be removed
from the unit. Another fi lter rack should be fabricated in
the return duct approximately 1 foot from the inlet of the
air handler, and the fi lter installed in this location.

1. Remove top and bottom doors. Remove the coil by

fi rst removing the screw securing the tube close-off
plate to the cabinet and then sliding the coil straight out
of the unit. Reposition the air handler in the downfl ow
position.

2. Unfold and install the adaptor kit, using the screws

provided, as shown in Figure 1. Holes for mounting
the downfl ow adaptor kit are provided in the air
handler.

3. Replace the indoor coil assembly and secure the

tube close-off plate to the cabinet. (See Figure 1)

4. Rotate the bottom door 180° from its original

orientation.

The air handler is now ready to be installed. See the
installation instructions included with the unit.

Table 1. Application Matrix

708530B (Replaces 708530A)

Specifi cations and illustrations subject to change

without notice and without incurring obligations.

Printed in U.S.A. (07/07)

INSTALLER:

PLEASE LEAVE THESE

INSTALLATION INSTRUCTIONS

WITH THE HOMEOWNER.

¢708530¥¤

708530B

Tube

Close-off

Plate

Coil

Cabinet

Adaptor Kit

Note: Shown in downflow
(drawthrough coil) position.

Part Number

Cabinet Size

Application

917342

A

Downfl ow Only

919321

B

Downfl ow Only

919322

C

Downfl ow Only

919323

C

Downfl ow Only

for B Width Coil