LP & HIGH ALTITUDE LP GAs CONVERsION KIT
FOR INsTALLATIONs IN THE UNITED sTATEs (0 -7,000 FT)

INsTALLATION INsTRUCTIONs

INsTALLERs: Please read all instructions before converting
the furnace.
Pay attention to all safety warnings and any other
special notes highlighted in the manual. Safety markings are
used frequently throughout this manual to designate a degree
or level of seriousness and should not be ignored. WARNING
indicates a potentially hazardous situation that if not avoided,
could result in personal injury or death. CAUTION indicates a
potentially hazardous situation that if not avoided, may result in
minor or moderate injury or property damage

This conversion kit is only to be used to convert a natural gas
unit to LP/Propane gas or to an LP high altitude application in
the United States. This kit may only be used in units installed
in altitudes between zero and 7,000 feet above sea level. For
installations in Canada, the Canadian conversion instructions
must be used.

IMPORTANT NOTE: DO NOT REMOVE OR DEFACE THE
ORIGINAL RATING PLATE.

This conversion kit is backwards compatible with (*)R4(M,N)
& R6GN (150-180 Model) units. Contact NORDYNE Technical
Services for more information on these appliances.

Table 1 is a detailed listing of components required for converting
light commercial units to LP Gas for altitudes between 0 & 7,000
feet. Please check the contents of the conversion kit with that of
the parts listing, and familiarize yourself with each component.

FOR (*)R4(M,N) & R6GN (150 / 180 MODELs) LIGHT COMMERCIAL PACKAGE GAs / ELECTRIC UNITs

Table 1. Conversion Kit Contents

DEsCRIPTION

QTY

Gas Valve (Nordyne P/N 624695)
(White Rodgers P/N 36H64-463B1)

1

Main LP Burners

7

White Rodgers Conversion Kit #F0092-1008
Converts Nordyne Valve - P/N 624695 (36H64-463B1)

1

#49 Drill Size Burner Orifice Kit (Contains 7)

1

#50 Drill Size Burner Orifice Kit (Contains 7)

1

#51 Drill Size Burner Orifice Kit (Contains 7)

1

Conversion Warning Label - P/N 703935

1

Conversion Information Label - P/N 710005

1

Installation Instructions - P/N 708393

1

The installer performing this work assumes all responsibility for this
conversion. These instructions are primarily intended to assist qualified
individuals experienced in the proper installation of these components.
Some local codes require licensed installation/service personnel for this
type of equipment. Safety should always be the deciding factor when
installing this product and using common sense plays an important role
as well. Improper installation of the components or failure to follow safety
warnings could result in serious injury, death, or property damage. After
completing the installation, return these instructions to the Homeowner’s
Package for owner-user’s future reference.

RIsQUE D’INCENDIE OU D’ EXPLOsION

• Le non-respect des avertissements de sécurité

pourrait entraîner des blessures graves, la mort ou
des dommages matériels.

• L’installation et l’entretien doivent être effectués par

un installateur qualifié, un organisme de service ou le

fournisseur de gazstaller, service agency or the gas

supplier.

• Ne pas entreposer ni utiliser de l’essence ni d’autres

vapeurs ou liquides inflammables dans le voisinage
de cet appareil, ni de tout autre appareil.

QUE FAIRE s’IL Y A UNE ODEUR DE GAZ

• Ne pas tenter d’allumer aucun appareil.
• Ne toucher à aucun interrupteur électrique; n’utiliser

aucun téléphone dans le bâtiment.

• Évacuer l’immeuble immédiatement.
• Appeler immédiatement le fournisseur de gaz en

employant le téléphone d’un voisin. Respecter à la

lettre les instructions du fournisseur de gaz.

• Si personne ne répond, appeler le service des incendies.

AVERTIssEMENT

DO NOT DEsTROY THIs MANUAL. KEEP IN A

sAFE PLACE FOR FUTURE REFERENCE.

FIRE OR EXPLOsION HAZARD

• Failure to follow safety warnings exactly could result

in serious injury or property damage.

• Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

• Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU sMELL GAs

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone

in your building.

• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

WARNING: