Date of manufacturer 2, Rating plate 2, Serial no. 2 – Reznor LDAP Parts Manuals User Manual

Page 2: Rating plate and serial no, Example of a model ldap rating plate, Decoding a serial no, References

Advertising
background image

Form P-LDAP, P/N 271892R1, page 2

Rating Plate and Serial No.

Example of a Model LDAP Rating Plate

First Element of the

Serial Number - Date of

Manufacturer

Rating Plate Key

Decoding a Serial No.

Example of a Serial No. BDF 79 X7 N 00000

Code Nos.

1 2 3 4 5

Code No. Explanation

1

Date of manufacture (see table below)

2

Type of ignition system

3

Type of gas valve

4

Gas (N = natural; L = propane)

5

Consecutive number (identification only)

REZNOR

®

MERCER, PA. USA 16137
MADE IN MEXICO
UNIT HEATER
CATEGORY III
ANSI Z83.8

[AA] [ A ] CSA 2.6 [AA’] [ A’ ] UNIT HEATER

MODEL [ B ] [ C ]
SERIAL NO.
[ D ]
VOLTS [ D ] PH [ D ] HZ MAXIMUM TOTAL INPUT [ D ] AMPS
TYPE OF GAS: [ E ]
FOR USE AT 0-2000 FEET, 0-610 METERS OF ALTITUDE.
ORIFICE SIZE [

F ] DRILL

NORMAL INPUT

[

J ] BTU/HR

THERMAL OUTPUT CAPACITY

[

L ] BTU/HR

MINIMUM INPUT

[

M ] BTU/HR

NORMAL MANIFOLD PRESSURE [

G ] IN.W.C.

MIN. PERMISSIBLE GAS SUPPLY PRESSURE
FOR PURPOSE OF INPUT

ADJUSTMENT.

[

H ] IN.W.C.

CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP -12 “,
FLUE CONNECTION - 6”, REAR -18”, SIDE -2 “, DISCONNECT SIDE

- 18”
BOTTOM - 60”, FRONT - 2”
FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS OF

THE APPROPRIATE STANDARD LISTED BELOW:
FOR AIRCRAFT HANGARS

USE STANDARD ANSI/NFPA 409

FOR PARKING STRUCTURES

USE STANDARD ANSI/NFPA 88A

FOR REPAIR GARAGES

USE STANDARD ANSI/NFPA 88B

THIS UNIT IS NOT FOR USE WITH DUCTS.
THIS UNIT IS NOT FOR USE WITH FILTERS.

A Date of ANSI Standard

A’ Date of CSA Standard

B Model No.

C Month and Year of Manufacture
D Voltage, Phase, 60 Hertz, Maximum Total

Input Amps

E Natural or Propane Gas

F Orifice Size

G Manifold Pressure (3.5”w.c. Natural Gas;

10”w.c. Propane Gas)

H Minimum Gas supply Pressure (5.0” w.c.

Natural Gas; 11.0” w.c. Propane Gas)

J BTU Normal Input Sea Level

L BTU Thermal Output Sea Level

M BTU Minimum Input Sea Level

Year

Jan

Feb

Mar

Apr

May

June

July

Aug

Sept

Oct

Nov

Dec

2004

BDA

BDB

BDC

BDD

BDE

BDF

BDG

BDH

BDI

BDJ

BDK

BDL

2005

BEA

BEB

BEC

BED

BEE

BEF

BEG

BEH

BEI

BEJ

BEK

BEL

2006

BFA

BFB

BFC

BFD

BFE

BFF

BFG

BFH

BFI

BFJ

BFK

BFL

2007

BGA

BGB

BGC

BGD

BGE

BGF

BGG

BGH

BGI

BGJ

BGK

BGL

2008

BHA

BHB

BHC

BHD

BHE

BHF

BHG

BHH

BHI

BHJ

BHK

BHL

2009

BIA

BIB

BIC

BID

BIE

BIF

BIG

BIH

BII

BIJ

BIK

BIL

2010

BJA

BJB

BJC

BJD

BJE

BJF

BJG

BJH

BJI

BJJ

BJK

BJL

2011

BKA

BKB

BKC

BKD

BKE

BKF

BKG

BKH

BKI

BKJ

BKK

BKL

2012

BLA

BLB

BLC

BLD

BLE

BLF

BLG

BLH

BLI

BLJ

BLK

BLL

2013

BMA

BMB

BMC

BMD

BME

BMF

BMG

BMH

BMI

BMJ

BMK

BML

2014

BNA

BNB

BNC

BND

BNE

BNF

BNG

BNH

BNI

BNJ

BNK

BNL

2015

BOA

BOB

BOC

BOD

BOE

BOF

BOG

BOH

BOI

BOJ

BOK

BOL

2016

BPA

BPB

BPC

BPD

BPE

BPF

BPG

BPH

BPI

BPJ

BPK

BPL

2017

BQA

BQB

BQC

BQD

BQE

BQF

BQG

BQH

BQI

BQJ

BQK

BQL

2018

BRA

BRB

BRC

BRD

BRE

BRF

BRG

BRH

BRI

BRJ

BRK

BRL

2019

BSA

BSB

BSC

BSD

BSE

BSF

BSG

BSH

BSI

BSJ

BSK

BSL

2020

BTA

BTB

BTC

BTD

BTE

BTF

BTG

BTH

BTI

BTJ

BTK

BTL

Printed Forms (Request by Form designation; not P/N) ........................ Form ....................P/N
Installation/Operation/Maintenance Manual - Model LDAP ....................I-LDAP .................207733
Gas Conversion Instructions ...............................................................I-LDAP-GC .............208881
High Altitude (above 6000 ft) Instructions ...........................................I-LDAP-HA..............208081
Website (downloadable files of all printed forms are on the Website)
www.ReznorHVAC.com

References

Advertising