Serial number and model codes, Serial no. decoding, Reznor – Reznor Valves Parts Manuals User Manual

Page 3: Models showing model and serial numbers, Rating plate key for maps, Maps, Unit rating plate showing model and serial numbers

Advertising
background image

Form P-VALVES, P/N 263995R4, Page 3

Example of a Rating Plate that applies to most Reznor

®

Models showing Model and Serial Numbers

Serial No. Decoding

DUCT FURNACE

CATEGORY I

FOR INDUSTRIAL/COMMERCIAL USE ONLY

NRTL

DESIGN CERTIFIED UNDER ANSI Z83.8a-1998

DUCT FURNACE

MODEL HX100E-8-S

OCT 2004

SERIAL# EBDJ66W8N12345

115 VOLTS 1PH 60HZ MAXIMUM TOTAL INPUT

.5AMPS

TYPE OF GAS NATURAL

ORIFICE SIZE #41

DRILL HAS BEEN FACTORY ADJUSTED

FOR USE AT

0-2000 FEET (0-610 METERS) OF ALTITUDE

SEA LEVEL

ALT ADJUSTED

NORMAL INPUT

100000

100000 BTU/HR

OUTPUT CAPACITY

80000

80000 BTU/HR

MIN. INPUT (2, M, MB, MV MODELS) 50000

50000 BTU/HR

NORMAL MANIFOLD PRESSURE

3.5 IN. W.C.

MIN. PERMISSIBLE GAS SUPPLY PRESSURE

FOR PURPOSE OF INPUT ADJUSTMENT

5.0 IN. W.C.

MAXIMUM THROUGHPUT

3704 CFM

MINIMUM THROUGHPUT

988 CFM

CLEARANCE TO COMBUSTIBLE CONSTRUCTION: TOP - 6";

FLUE CONNECTION - 6"; SERVICE SIDE - WIDTH OF UNIT;

OPPOSITE SIDE - 6"; BOTTOM - 3", MAY BE INSTALLED ON

NONCOMBUSTIBLE FLOORS.

INSTALL ON THE POSITIVE PRESSURE SIDE OF AIR

CIRCULATING BLOWER.

THIS UNIT MAY BE INSTALLED DOWNSTREAM FROM A

REFRIGERATION SYSTEM (USE DRAIN OPTION CS1).

FOR ALTERNATE INSTALLATION, USE THE LATEST OF THE

APPROPRIATE STANDARDS LISTED BELOW:

FOR AIRCRAFT HANGARS

USE STANDARD ANSI/NFPA 409

FOR PARKING STRUCTURES USE STANDARD ANSI/NFPA 88A

FOR REPAIR GARAGES

USE STANDARD ANSI/NFPA 88B

®

Mercer, PA 16137

Serial Number and Model Codes

Sample of a Serial No. for Units manufactured from 1963 through

1974:

OA 1

2

N

693

Serial No.

1

2

3 4 5

Element

Sample of a Serial No. for Units manufactured beginning in 1975:

BDJ 66

W8

N

12345 Serial No.

1 2 3 4 5 Element

Element Key:
1 = Month and Year of manufacture; see page 4.
2 = Type of safety pilot or ignition system; see pages 6-10 for Code

explanation.

3 = Type of valve; see pages 12-22 for Code explanation and illustra-

tions on pages 23-27. (A dash indicates that the valve was field

supplied.)

4 = Type of gas that the heater was originally manufactured to burn
D = Dual fuel, natural and propane; L = Propane; N = Natural

(Check for gas conversion label.)

5 = Consecutive number of heater manufactured. Used for identifi-

cation purposes only.

In addition to the basic five elements, the serial number may also include

prefix and/or suffix codes. See page 5 for a listing and explanation of

these codes. All codes apply to original equipment only.

REZNOR

®

MERCER, PA, U.S.A. 16137

MADE IN USA

FOR INDUSTRIAL/COMMERCIAL USE ONLY

SUITABLE FOR OUTDOOR USE

MODEL [ A ]

[ B ]

SERIAL NO. [ ]

ELECTRICAL

[D] VOLTS +/- 10% [D] PHASE [D] HZ

MINIMUM CIRCUIT AMPACITY (MCA)

[ F ] AMPS

MAXIMUM FUSE SIZE/*CKT BREAKER

[ G ] AMPS

QTY

FLA (EA)

HP (EA)

SUPPLY AIR BLOWER MOTOR

1

[ E ]

[ C ]

CONDENSER FAN MOTOR (S)

[ T ]

[ U ]

[ Z ]

QTY

RLA (EA)

LRA (EA)

COMPRESSOR A

[ H ]

[ I ]

[ J ]

COMPRESSOR B

[ K ]

[ L ]

[ M ]

COMPRESSOR C

[ N ]

[ O ]

[ P ]

COMPRESSOR D

[ Q ]

[ R ]

[ S ]

COMPRESSOR E

[ GG ]

[ HH ]

[ II ]

CIRCUITS

A

B

C

D

E

REFRIGERANT -

R-410a CHARGE - LBS

[ V ] [ W ] [ X ] [ Y ] [ JJ ]

TEST PRESSURES

HIGH

600PSIG LOW

45PSIG

EQUIPPED FOR OPERATION AT AN AIR FLOW OF

[ CC ] SCFM

AGAINST A STATIC PRESSURE OF

[ DD ] INCHES WATER COLUMN

DRIVE RPM

[ EE ]

WIRE DIAGRAM

[ FF ]

REFER TO RATING PLATE IN THE FURNACE SECTION (WHEN USED)

FOR ADDITIONAL INFORMATION.

*HACR TYPE REQUIRED PER NEC

Rating Plate Key for MAPS

®

Model Series RCA,

RDA, RCB, RDB, RCC, and RDC

(NOTE: To decode a MAPS Serial No., see page 4.)

Example of a Reznor

®

MAPS

®

Unit Rating Plate

Showing Model and Serial Numbers

CC = SCFM Airflow

DD = External

Static Pressure

(“ w.c.)

EE = Drive (Option

AM)

FF = Wiring Dia-

gram No.

GG = Quantity -

Compressor E

HH = Rated Load

Amps of Com-

pressor E

II = Locked Rotor

Amps of Com-

pressor E

JJ = Refrigerant

Charge (lbs) -

Circuit E

A = Model

B = Manufacturing Date (Month/Year)

C = Blower Motor HP

D = Volts/Phase/Hertz

E = Full Load Amps (FLA) of Blower Motor

F = Minimum Circuit Ampacity (MCA)

G = Maximum Fuse Size (MOP)

H = Quantity - Compressor A

I = Rated Load Amps of Compressor A

J = Locked Rotor Amps of Compressor A

K = Quantity - Compressor B

L = Rated Load Amps of Compressor B

M = Locked Rotor Amps of Compressor B

N = Quantity - Compressor C

O = Rated Load Amps of Compressor C

P = Locked Rotor Amps of Compressor C

Q = Quantity - Compressor D

R = Rated Load Amps of Compressor D

S = Locked Rotor Amps of Compressor D

T = Quantity Condenser Fan Motors

U = Rated Load Amps of Condenser(s)

V = Refrigerant Charge (lbs) - Circuit A

W = Refrigerant Charge (lbs) - Circuit B

X = Refrigerant Charge (lbs) - Circuit C

Y = Refrigerant Charge (lbs) - Circuit D

Z = Condenser Fan Motor HP