Alves 25, Code 174 - gas valves – Reznor MAPSII Series Parts Manuals User Manual

Page 26

Advertising
background image

P-MAPS II, PN 271467R1, Page 25

CODE 174 - Gas Valves

(For functional replacement valve by Serial No. Code, see Form P-VALVES.)

Single Stage Gas

Valves in both AG55

and AG57 Controls

Modulating

Gas Valve

in AG57 6:1

Gas Controls

1st

Single-Stage

Gas Valve

2nd Single-Stage

Gas Valve

165 - Optional Low

Gas Pressure Switch

166 - Optional High

Gas Pressure

Switch (manual

reset)

166 - Optional High Gas Pressure

Switch (manual reset)

To 2/3 burner

To 1/3

burner

157 - Orifice Adapter

156 - Orifice Adapter

2nd

Single-Stage

Gas Valve

Electronic Modulating/Regulating

Valve for Optional 6:1 /turndown

(See table above for P/N by Size)

1st

Single-Stage

Gas Valve

165 - Optional Low

Gas Pressure

Switch

166 - Optional

High Gas

Pressure Switch

(manual reset)

to 1/3 burner

to 2/3 burner

Gas Train

Layout - Sizes

100, 150, 200,

250, 300, 350,

400 with AG55

3:1 Gas Controls

and Optional

Pressure

Switches

Gas Train Layout - Sizes 100, 150,

200, 250, 300, 350, 400 with AG57 6:1

Gas Controls and Optional Pressure

Switches

Inlet Gas Pipe

Size 100-300, 1/2”; Size 350-400, 3/4”

Inlet Gas Pipe

Size 100-300, 1/2”

Size 350-400, 3/4”

Sequence of Operation:

The 1/3 burner valve and the 2/3 burner

valve are energized. After 20 seconds the

1/3 burner valve is de-energized (this is

Stage 1).

For

Stage 2, the full (non-split) burner

valve and the 1/3 burner valve are

energized, while the 2/3 burner valve is

de-energized.

Stage 3 brings the 2/3 burner valve back

on so all valves are energized.

To 2/3

Burner

Section

To 1/3

Burner

Section

Two Orifices To

Full Burner Section

Single-Stage Valve

controlling flow to

Full (non-split) Burner

Single-Stage

Valve

controlling

flow to

2/3 Burner

Single-Stage

Valve

controlling

flow to

1/3 Burner

Inlet Gas Pipe

Size 450-700, 1”

STAGE 1

STAGE 2

STAGE 3

Gas Train Layout - Sizes 450, 500, 550, 600,

650, 700 with AG55, 3:1 Gas Controls

CODE 175 -

Maxitrol Signal

Conditioner

used with

AG57 6:1 Gas

Control, P/N

134170

P/N Description

260603 1/2” Single-Stage Valve, VR8215T1239, Natural Gas

See

applications

in illustrations

below.

196981 3/4” Single-Stage Valve, VR8305K4241, Natural Gas

263999 1/2” Single-Stage Valve, VR8215T5214, Propane

196983 3/4” Single-Stage Valve, VR8305K4258, Propane

205582 Maxitrol Modulating Valve, MR410, Heat Section Sizes 100 & 150

205581 Maxitrol Modulating Valve, MR410-1, Heat Section Size 200

205580 Maxitrol Modulating Valve, MR510, Heat Section Sizes 250 & 300

208370 Maxitrol Modulating Valve, 3/4”, MR610-1-66, Heat Sctn Sizes 350 & 400
208371 Maxitrol Modulating Valve, 1”, MR610-1-88, Heat Section Sizes 450, 500,

550, 600, 650, & 700

Replacement

Valves

P/N 260603

P/N 263999

P/N 196981

P/N 196983