INSTALLATION INSTRUCTIONS

FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION

.

AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.

MINIMUM HOLE SIZE FOR THE SPOUT AND HANDLE TRIM IS 1

1/4

” AND MAXIMUM OF 1

1/2

VACUUM BREAKER INSTALLATION

1
- Remove the complete vacuum breaker trim (1) from the cartridge (03).
From the underneath of the sink, insert the vacuum breaker cartridge (03) through the
center hole of the sink with the one of 2 conical black Soft Seating China Seals inserted.
- From the top of the sink, insert the second black Soft Seating China Seal, the White Nylon
Slip Washer, then the black Plastic Inverted Lock Nut onto the Cartridge (03).
Tighten it firmly.
- Screw the Trim Cylinder onto the Cartridge (03). Tighten Firmly.
- Slip the Handle onto the Cartridge stem and secure it with the brass screw.
- Clip the Handle Cap onto the Handle after the installation is complete to check for the
water flow options.

HANDLE TRIM INSTALLATION

1
- For proper handle turning direction, install the handle with the “cold” blue label (7)
at the right side of the sink (looking from the front) and the handle with the “hot”
red label at the left side of the sink.
- Both hot and cold side handle trims are pre-assmbled for faster installation.
- Remove the bottom valve body mounting hardware (10) from the valve body.
Slip the valve body’s flexible hoses from the top of the sink or counter through
the appropriate hole next to the vacuum breaker.
Aim the tee connecting hoses (8) toward the Y- connector (12).

2
- From beneath of the basin or counter, screw the valve body bottom mounting
hardware (10) back to the valve body. First the fiber washer, then the brass
lock nut.
- Align the lever handle properly against the sink.
Tighten the lock nut until it secures the valve body firmly.

3
- Loop and connect the flexible hoses (8) to the Y-Connector (12). Tighten to avoid
leakage.
- Connect and tighten the Inlet hoses (9) to the supply lines.