8

Polyphonic Key Pressure

Format

Send
This message is not sent by this Instrument.

Receive
This message is not received by this Instrument.

9

Control Change

Format

Send

Sent when the Instrument's pedal is operated or when Instrument settings are changed.

Receive

Receipt changes the Instrument mode or the corresponding parameter.

9.1

Bank Select (00H)

Format

Send

Sent when a tone is selected. See the Tone List in the Instrument's User's Guide for details.

Receive

Receipt causes a change in the tone bank number stored in Instrument memory, but the tone is not actually changed until
a Program Change message is received.
For details, see "11 Program Change" in this document, and the Tone List in the Instrument's User's Guide.

Message Format: AnH kkH vvH

n: MIDI Channel Number

kk: Key Number
vv: Pressure Value

Message Format: BnH ccH vvH

n: MIDI Channel Number

cc: Control Number
vv: Value

Message Format: BnH 00H vvH (MSB)

BnH 20H **H (LSB)

n: MIDI Channel Number

vv:
**:

Value
Ignored