UART sleep/wakeup triggers on/off. Each of the two

parameters can be specified as “on” or “off”. The first
parameter specifies sleep trigger (UART inactivity
timeout) setting, second – wakeup trigger (low pulse on
UART Rx input) setting. The defaults are sleep = off,
wake = on.

SLUIT sec

Set UART inactivity timeout. The parameter is

specified in seconds (decimal). The default is 1200
(20 minutes).

SLUWP min, max

Set UART wakeup pulse timing. The parameters

are specified in microseconds. The defaults are min =
0, max = 30000 (30 ms).

SLX sleep, wakeup

External sleep trigger on/off. Enables/disables

sleep/wakeup triggers for the external sleep control
input (SLEEP). Each of the two parameters can be
specified as “on” or “off”. The first parameter specifies
the sleep trigger (SLEEP input low) setting, and the
second specifies the wakeup trigger (SLEEP input
high) setting. The defaults are sleep = off, wake = on.

SLXP 0/1

Set polarity of the external sleep control input.
0: LOW = enter sleep, HIGH = wake up
1: LOW = wake up, HIGH = enter sleep
The default setting is 0.
Note: This command is available only for STN1110

stand-alone IC and microOBD 200 (STN1120).

SLXS

Print external SLEEP input status. Responds with

“WAKE” or “SLEEP”.

SLXST ms

Set minimum active time for external sleep trigger

before entering sleep. Sets the length of time in
milliseconds the external sleep control input must
remain in the active (logic low) state, before the device
enters sleep mode. The default is 3000 (3 seconds).

SLXWT ms

Set minimum inactive time for external sleep trigger

before wakeup. Sets the length of time in milliseconds
the external sleep control input must be held in the
inactive (logic high) state before the device wakes from
the sleep mode. The default is 2000 (2 seconds).


6.4 CAN Specific ST Commands

CAFCP ttt, rrr

Add a flow control 11-bit CAN ID pair. Takes two

three-digit parameters: ttt is transmitter ID, and rrr is
receiver ID. For example, STCAFCP 7E0,7E8.

CCFCP

Clear all flow control 11-bit ID pairs.


6.5 ISO Specific ST Commands

IAT 0/1

Turn ISO adaptive P

1

max timing off/on*. When this

mode is on, maximum interbyte time (P

1

max) for

ISO 9141 messages is adaptively reduced to allow
communication with some ECUs that do not comply
with the minimum intermessage time (P

2

min) specified

in ISO 9141-2 standard. It is on by default.

IBR baud

Set ISO baud rate. Takes a decimal parameter,

expressed in bits per second (bps). Supported baud
rates are 612 to 65535 bps (65.5 kbps).

IMCS 0/1

Turn ISO manual checksum off*/on. When this

setting is on, STN11xx will not automatically append
checksum byte for transmitted messages, or verify
checksum for received messages. Additionally, for
KWP2000 protocols (4 and 5), minimum allowed OBD

request length is increased to 2 bytes (one data byte
and checksum).

IP1X ms

Set maximum interbyte time for receiving ISO

messages (P

1

max). Takes a decimal parameter in

milliseconds. Default is 20 ms.

IP4 ms

Set interbyte time for transmitting ISO messages

(P

4

). Takes a decimal parameter in milliseconds.

Default is 5 ms.