Sleep [delay, Sllt, Slpcp 0|1 – ScanTool STN11xx User Manual

Page 10: Table 1 for the d, Table 1 co, Stn11xx powersave

Advertising
background image

STN11xx PowerSave

Table 1 – PowerSave Configuration Summary Detail

Configuration Summary Line

Sec. Description

CTRL MODE: <NATIVE/ELM327>

1.1

PowerSave control mode.

Reports whether

PowerSave module is operating in a native
PowerSave

control mode, where all settings are

configured via the ST commands, or an ELM327 Low
Power

compatibility mode, where some settings are

overridden via the ELM327 programmable parameter
0E.

PWR_CTRL: LOW PWR = <LOW/HIGH>

1.5

PWR_CTRL output pin polarity

. Specifies whether

the pin outputs a logic LOW or HIGH in low power
mode.

UART SLEEP: <ON/OFF>, <timeout> s

1.2.2 UART inactivity sleep trigger:

<ON/OFF>

trigger

on/off

<timeout>

inactivity timeout setting in
milliseconds

UART WAKE: <ON/OFF>, <pulse min>-<pulse max> us

1.3.1 UART Rx pulse wakeup trigger:

<ON/OFF>

trigger

on/off

<pulse min>

minimum UART Rx pulse width
in microseconds

<pulse max>

maximum UART Rx pulse width
in microseconds (0 = no
maximum)

EXT INPUT: <LOW/HIGH> = SLEEP

1.2.3 SLEEP input polarity. Specifies whether it takes a

LOW

or a HIGH on the SLEEP pin to put the device

to sleep.

EXT SLEEP: <ON/OFF>, <LOW/HIGH> FOR <time> ms

1.2.3 External SLEEP input sleep trigger:

<ON/OFF>

trigger

on/off

<LOW/HIGH>

specifies the active logic level

<time>

specifies how long the SLEEP
input must be held in the active
(“sleep”) state to put the device
to sleep.

EXT WAKE: <ON/OFF>, <LOW/HIGH> FOR <time> ms

1.3.2 External SLEEP input wakeup trigger:

<ON/OFF>

trigger

on/off

<LOW/HIGH>

specifies the active logic level

<time>

specifies how long the SLEEP
input must be held in the
inactive (“wake”) state to wake
the device from sleep.

VL SLEEP:

<ON/OFF>, <</>>[!]<level> FOR <time> s

1.2.4 Voltage level sleep trigger:

<ON/OFF>

trigger

on/off

<</>>

specifies whether the trigger
region is below (<) or above (>)
the <level> threshold setting

[!]

this designator indicates that the
trigger voltage setting is invalid,
i.e. cannot be achieved with the
current voltage calibration

© 2009 ScanTool.net, LLC

www.ScanTool.net

STN11XXDSB

Advertising