Ector, Yroelectric, Etector – Scientech Vector User Manual

Page 3: Pecifications, Ertification, Nvironmental, Equirements

Advertising
background image

3

V

ECTOR

P

YROELECTRIC

D

ETECTOR

S

PECIFICATIONS

:

Model

P 25

PHF 25

PHD 25

PHDX 25 PHDX25UV

SP 25

SPHF 25

SPHD 25

Aperture Diameter

25.4 mm

25.4 mm

25.4 mm

7mm

7mm

25.4 mm

25.4 mm

25.4 mm

Spectral Response

.193-10.6µm

.4-2µm

.193-2µm

.193-10.6µm

Maximum Average Power
Minimum Energy
Noise Equivalent Energy

4 µJ

Maximum Energy Density

Note 2

Note 3

Note 4

Note 2

Peak Power Density

100MW/cm

2

800MW/cm

2

400MW/cm

2

100MW/cm

2

Accuracy

5%

5%

8%^

8%^

8%^

5%

5%

8%^

Output Sensitivity

8 V/J

8 V/J

2 V/J

2 V/J

2 V/J

8 V/J

8 V/J

2 V/J

Maximum Repetition Rate

100 pps

400 pps

40 pps

40 pps

40 pps

100 pps

400 pps

40 pps

Maximum Pulse Duration

0.2 msec

0.045 msec

0.2 msec

0.2 msec

0.2 msec

0.2 msec

0.045 msec

0.2 msec

Dimensions D x L - inches

2.4 x 2.3

2.4 x 2.3

2.4 x 2.3

2.4 x 3.9

2.4 x 3.9

2.3x2.3x0.6 2.3x2.3x0.6 2.3x2.3x0.6

cm

6.1 x 5.8

6.1 x 5.8

6.1 x 5.8

6.1 x 9.9

6.1 x 9.9

5.8x5.8x1.4 5.8x5.8x1.4 5.8x5.8x1.4

Weight - pounds/kgs

0.9/1.4

0.9/1.4

0.9/1.4

1.1/0.5

1.1/0.5

0.3/0.14

0.3/0.14

0.3/0.14

Indicator Compatibility

H410, H410D, S310, S310D, D200PC, D200P

Model

P 50

PHF 50

PHD 50

PHDX 50 PHDX50UV

SP 50

SPHF 50

SPHD 50

Maximum Beam Diameter

50.8 mm

50.8 mm

50.8 mm

15 mm

15 mm

50.8 mm

50.8 mm

50.8 mm

Spectral Response

.193-10.6µm

.4-2µm

.193-2µm

.193-10.6µm

Maximum Average Power
Minimum Energy
Noise Equivalent Energy
Maximum Energy Density

Note 2

Note 3

Note 4

Note 2

Peak Power Density

100MW/cm

2

800MW/cm

2

400MW/cm

2

100MW/cm

2

Accuracy

5%

5%

8%^

8%^

8%^

5%

5%

8%^

Output Sensitivity
Maximum Repetition Rate

50 pps

400 pps

20 pps

20 pps

20 pps

50 pps

400 pps

20 pps

Maximum Pulse Duration

0.4 msec

0.045 msec

0.4 msec

0.4 msec

0.4 msec

0.4 msec

0.045 msec

0.4 msec

Dimensions D x L - inches

3.5 x 2.3

3.5 x 2.3

3.5 x 2.3

3.5 x 3.9

3.5 x 3.9

3x3x0.6

3x3x0.6

3x3x0.6

cm

8.8 x 5.8

8.8 x 5.8

8.8 x 5.8

8.8 x 9.9

8.8 x 9.9

7.6x7.6x1.5 7.6x7.6x1.5 7.6x7.6x1.5

Weight - pounds/kgs

1.5/0.68

1.5/0.68

1.5/0.68

1.7/0.77

1.7/0.77

0.4/0.18

0.4/0.18

0.4/0.18

Indicator Compatibility

H410, H410D, S310, S310D, D200PC, D200P

^Beam centered on absorber
Note 1:

Max J/cm2 =316 x (pulse width)1/2

Note 2: HD models

Max J/cm

2

= 4500 x (pulse width)

1/2

to a maximum of 1.4 J/cm

2

.

Maximum pulse width of the pyroelectric detector must be observed.

Note 3: HDX models

Max J/cm

2

= 36,000 x (pulse width)

1/2

to a maximum of 12.6 J/cm

2

.

Maximum pulse width of the pyroelectric detector must be observed.

Note 4: HDXUV models Max J/cm

2

= 18,000 x (pulse width)

1/2

to a maximum of 5.6 J/cm

2

.

Maximum pulse width of the pyroelectric detector must be observed.

5 W with full illumination of the detector

10 W with full illumination of the detector

.193-26µm

.193-26µm

.193-26µm

.193-26µm

7% of selected range

n/a

n/a

n/a

n/a

2 V/J

Note 1

Note 1

Note 1

Note 1

16 µJ

7% of selected range

CE

M

ARK

C

ERTIFICATION

:

All of the pyroelectric detectors listed in this manual have been certified for the European CE mark.

E

NVIRONMENTAL

R

EQUIREMENTS

:

This product is intended for indoor use at altitudes up to 2000 meters, Pollution Degree 2 in accordance with
IEC 664 and transient overvoltages according to Installation Categories (Overvoltage Categories) II. Note that
each of the above detectors will not pass the IEC 801 Publication, Part 3, Radiated Electromagnetic Field
Requirements. The system, meter and detector, is designed to measure radiation within the test's radiation band.
The detectors were held outside the radiated electromagnetic field during this test. It is up to the user to be
aware of RF fields present during measurements and their effects if any on those measurements.

Advertising