SeaLand 970 Series MSD Fittings User Manual

Installation, Msd discharge fitting for dometic, 970 series portable toilets

Advertising
background image

InstallatIon

BE SURE TO READ INSTRUCTIONS COMPLETELY BEFORE INSTALLATION.

MsD DIsCHaRGE FIttInG FoR DoMEtIC

®

970 sERIEs

PoRtaBlE toIlEts

® Registered; ™ Trademark of Dometic Corporation
© Dometic Corporation
600345664-INTL 4/09

Hose ID

Discharge

1.5 inch/38 mm

Vent

.625 inch/16 mm

PLUMBING SPECIFICATIONS

A

Tie-wrap

Discharge elbow adapter

Discharge fitting

Vent fitting

B

C

Holding

Tank

MSD

Discharge

Fitting

EN

NOTE: Dometic 970 series portable toilet should be permanently
installed with floor mounting brackets (385311564 or 860003853200056)
before installing MSD discharge fitting. Allow 2.75 inches (70 mm) clearance
between back of toilet and wall for MSD discharge fitting.

1. Remove discharge spout from top of holding tank by turning it

counterclockwise until it unlocks (see illustration A) and pulling it out of
tank.

2. Lubricate two small O-rings on discharge fitting with silicone grease and

attach discharge elbow adapter to discharge fitting. Secure adapter in
place with plastic tie-wrap (see illustration B).

3. Lubricate large O-ring on discharge fitting and insert discharge fitting

assembly into holding tank. Rotate it so that discharge and vent
fittings point away from tank (see illustration C).

4. Using hose clamp, attach 1.5-inch (38 mm) ID discharge hose over end

of elbow adapter. Make sure discharge hose(s) connect securely to all
discharge fittings.

5. Using hose clamp, attach 0.625-inch (16 mm) ID vent hose to vent fitting.

Make sure vent hose connects securely to through-hull vent fitting.

DoMEtIC CoRPoRatIon, sanItatIon DIVIsIon
13128 sR 226 | Po BoX 38 | BIG PRaIRIE, oHIo 44611 Usa
www.Dometicsanitation.com