insTallaTion

component

location

checklist

Vacuum toilet

Bathroom

compartment

1. Check dimensions of mounting space.

2. Determine best toilet discharge connection: right, left or rear

discharge (above floor only).

3. Allow at least 1½-inch (38 mm) clearance between toilet rear

and wall.

4. Make sure compartment, shower and vanity doors will clear

toilet bowl.

5. Check location nearest cold water line.

6. Water line must be at least ½-inch ID and provide a minimum

flow of 2 gallons per minute (7.6 liters per minute).

7. Check clearances to side wall for installation of flush lever

cover and back wall for best clearance.

Vacuum holding

tank (VHT)

Any space that

permits access

to remove entire

unit

1. The vacuum holding tank inlet must be located no more than

20 feet (6.1 m) from the toilet discharge.

2. The VHT inlet must not be located more than 3 feet (0.9 m)

above the outlet of the toilet. (NOTE: The lower the tank, the

better the system efficiency.)

3. The VHT must be mounted in a horizontal position.

4. The VHT must not be exposed to temperatures over 120°F

(49°C). Do not place near heat sources such as engine

manifolds, water heaters, generators, etc. Mounting space

must provide for free air flow.

Vacuum hose

and fittings

Follow routing

instructions

1. OdorSafe Plus Sanitation Hose should be used; it is sized to

use SeaLand fittings in the system, minimizing vacuum

leakage.

2. It is important that restrictions in the vacuum hose be kept to

a minimum. Where a bend must occur in a hose run, the ra-

dius of the bend must not be less than 8.5 inches (216 mm).

If a tighter radius is required, use a SeaLand 90° bend kit to

assure a clog-free transition.

locaTinG ThE coMPonEnTs

insTallinG VacuuM ToilET

1. Toilet must be installed on a horizontal surface, and

located so that the toilet seat can be lifted and the

foot pedal operated without interference from other

fixtures.

2. Place toilet in desired location at least 1.5 inches

(38 mm) from back wall.

3. Use screws included to fasten toilet to floor. Cover

screw heads with caps provided.

4. Attach 1/2” ID water supply pipe or hose from water

system to 1/2” NPT connection on back of water valve.

5. Connect sanitation hose to toilet discharge fitting by following same instructions for attaching

hose to vacuum holding tank (see page 7).