SeaLand 8800 Series MasterFlush - RV Installation Appendix User Manual

Rv installation appendix, 8800 series masterflush, Macerator toilets

Advertising
background image

wiring / electronic control Module connections

WARNING! HAZARD OF

SHOCK OR FIRE – Always

use recommended fuse, circuit

breaker and wire size. Failure to do

so can result in fire that can cause

the loss of property and life.

IMPORTANT INSTALLATION NOTES

• Each toilet must have its own medium-delay circuit

breaker or fuse.

• Wire sizes must be appropriate for the installation. All

other installation factors must be in accordance with

ISO electrical standards.

• Always use stranded copper wire (preferably tinned).

• Always use crimp-type wire connections. Do not use

wire nuts (they corrode).

CONvERSION TAbLES

Wire – AWG to mm

2

Feet to Meters

AWG

14

12

10

Ft

10

15

20

30

50

mm

2

2.5

4.0

6.0

M

3.1

4.6

6.1

9.2

15.2

Wire size per length of run*

0-15 ft.

16-30 ft.

31-50 ft.

12 volts DC

#14

#12

#10

* Distance from circuit breaker to electronic control module.

WIRE SIZING CHART

® Registered; ™ Trademark of Dometic Corporation

Dometic Corporation

600345328 5/08

When installing a SeaLand macerator toilet in a recreation vehicle, please use the following

Wiring information. Refer to SeaLand 8800 series owner’s manual (600345326), page 10,

for complete SeaLand macerator toilet wiring diagram.

8800 series MAsTerFlush

MACerATOr TOileTs

rV iNsTAllATiON APPeNDiX

Advertising