SIGTRONICS’ EGT 101 INSTALLATION INSTRUCTIONS

The Sigtronics’ EGT 101 Digital Exhaust Gas

Temperature meter is designed for mounting in the
conventional 2.25” instrument panel cutout. Parts
Supplied: 4 ea. mounting screws, power supply cable,
back-lighting kit.

BACK LIGHTING KIT - Prior to mounting the EGT,

determine the aircraft’s electrical system voltage. Then
select the proper voltage lamp from the backlighting kit.
The kit consists of a lamp socket and two wedge base
incandescent lamps.

For 12V electrical systems, install the #73 lamp into

the lamp socket. A 24V system requires the #85 lamp.
(The lamp identification numbers appear on the bulb’s
glass envelope).

Install the lamp/socket assembly into the hole on the

rear of the instrument case by inserting and rotating 1/8
turn clockwise.

PIN NO.

COLOR

FUNCTION

CONNECT TO

1

RED

EGT Power Input
12V or 24V

Power through 1 amp inline fuse or
appropriate circuit breaker.

2

BLACK

EGT Power Ground

Aircraft Chassis Ground

3

WH/RED

EGT Back-Light Power

Avionics Panel Lighting Dimmer Control

4

WH/BLACK

EGT Back-Light Ground

Aircraft Chassis Ground

THERMOCOUPLE (Probe) CONNECTIONS
Two threaded studs protrude from the rear of the
instrument case to accommodate connections of the K
type thermocouple (chromel/alumel) probe to the EGT.
First, remove the outermost nuts from the smaller of the

two studs (8-32) and install the negative (Red) thermo-
couple lead. Likewise, install the positive (Yellow)
thermocouple lead to the larger (10-32) stud on the EGT.
Hand tighten both terminal securing nuts. DO NOT
OVERTIGHTEN!

ELECTRICAL CONNECTIONS

Advertising