Led coding -2, Self tests -2, 3 led coding – SkyHunter406 SKYHUNTER 406 HF User Manual

Page 40: 1 self tests, 1 arm test

Advertising
background image

MANL:INS:SH:X:XX

August 8 ,2013

Rev 25

7-2

7.3

LED CODING

You will notice specific LED codes flashing on your ELT’s LED or the ELT on the Remote Rocker
Switch, these codes and meanings are described below

7.3.1 Self Tests

There are separate self tests available on the SkyHunter406 ELT’s as follows:

7.3.1.1

Arm Test

CAUTION: This Self Test uses battery power and as a result if you choose to perform more
than the recommended monthly testing early battery replacement may be required.

Place the ELT locking Master Switch in the “ARM” position.

With the ELT already in the “ARM” position, press the “RESET” at the Remote Switch.

During the self test there will be a series of flashes from the LED that needs to be interpreted.
Please use the table to identify the appropriate codes indicated. CAUTION: The unit should not
be switched to the “ON” position except in the case of an EMERGENCY.

LED Sequences Displayed

At the REMOTE SWITCH

At the ELT

Description

1 Red Flash*

1 Green Flash

Normal and Ready

3 Red Flashes*

3 Amber Flashes

Battery Voltage Low/Accumulated Battery
Time Limit Exceeded

4 Red Flashes*

4 Amber Flashes

Abnormal Hardware Conditions RETURN TO
MANUFACTURER FOR REPAIR

5 Red Flashes*

5 Amber Flashes

Not Programmed RETURN FOR
PROGRAMMING TO AN APPROVED
MAINTENANCE FACILITY

Table 2 – Self Test LED Coding

*For every Red Flash the buzzer will sound.

Advertising