2galaxy, Boiler dimensions – Slant/Fin GXH-190 User Manual

Page 2

Advertising
background image

2

GALAXY

ORIFICE SIZES

indicated for Sea Level are factory installed in

boiler unless otherwise specified by the local authority.
See VII, page 21 for burner input adjustment.

GAS VALVE CONNECTION

Size is 1/2" f.p.t. for all sizes up to and

including GG-300. Larger boilers, gas valves is 3/4".

COMBUSTIBLE FLOOR KIT

increases all height dimensions by 1".

RAISED SLAB

- When mounting boiler on a raised slab, the slab

must extend at least 2" beyond the boiler cabinet on all sides.

CHIMNEY HEIGHT:

15 ft. minimum from draft hood skirt to top of

chimney.

CHIMNEY INSIDE DIAMETER

must be same as Dimen-

sion “C” or larger. Larger diameter and/or height may be required if
two or more boilers or a boiler and another appliance are vented to
a single chimney.

GG-75H

GG-100H GG-125H GG-150H GG-175H GG-200H GG-225H GG-250H GG-275H GG-300

GG-350H GG-375H GG-399H

A

19

3

4

19

3

4

19

3

4

23

23

26

1

2

26

1

2

29

3

4

29

3

4

33

1

4

36

1

2

36

1

2

36

1

2

B

13

1

4

13

1

4

13

1

4

16

1

2

16

1

2

20

20

23

1

4

23

1

4

26

3

4

30

30

30

C

5

6

6

6

7

7

7

8

8

8

9

10

10

D

46

3

8

53

1

4

55

1

4

53

1

4

53

1

4

57

1

2

57

1

2

59

5

8

59

5

8

59

5

8

66

1

8

59

5

8

66

5

8

E

6

3

4

13

15

13

13

16

16

17

17

17

22

1

2

15

22

F

8

8

8

9

3

4

9

3

4

11

1

4

11

1

4

13

13

14

3

4

16

1

4

16

1

4

16

1

4

G

1

1

4

1

1

4

1

1

4

1

1

4

1

1

4

1

1

4

1

1

4

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

H

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

J

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

2

3

4

K

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

9

1

4

GXH-105 GXH-125 GXH-150 GXH-170

GXH-190

A

23

23

26

1

2

26

1

2

26

1

2

B

16

1

2

16

1

2

20

20

20

C

5

6

7

7

7

D

46

3

8

53

1

4

55

1

2

55

1

2

55

1

2

E

6

3

4

13

14

14

14

F

9

3

4

9

3

4

11

1

4

11

1

4

11

1

4

G

1

1

4

1

1

4

1

1

4

1

1

4

1

1

2

H

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

J

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

K

9

3

4

9

3

4

9

3

4

9

3

4

9

3

4

GG SERIES HOT WATER BOILERS - DIMENSIONS IN INCHES

GXH HOT WATER BOILERS - DIMENSIONS IN INCHES

FRONT VIEW

All GG and GXH

RIGHT SIDE

GG / GXH-PT

GG

Natural

42

43

43

43

43

44

44

45

46

47

Except GG-399H

Propane

54

54

55

55

55

55

55

56

56

56

GG-399H

Natural

40

41

42

42

42

43

43

44

44

45

Propane

53

54

54

54

54

54

54

55

55

55

GXH-105

Natural

44

45

45

45

46

47

47

48

48

49

through 190

Propane

54

54

55

55

55

55

55

56

56

56

Natural

GG-350H

Gas*

43

44

44

44

45

45

46

47

47

48

BOILER MODEL

GAS TYPE

2,000

ELEVATION–FEET

ORIFICE SIZES AT HIGH ALTITUDES

INCLUDES 4% INPUT REDUCTION FOR EACH 1000 FEET

3,000

4,000

5,000

6,000

7,000

8,000

9,000

10,000

Orifice

Size for

Sea Level

*For L.P. Propane gas, consult factory.

BOILER DIMENSIONS

ROLLOUT
SAFETY
SWITCH

TRANSFORMER
120/24V

TEMPERATURE/
PRESSURE
GAUGE

GAS VALVE

IGNITION
CONTROL

WATER
TEMPERATURE
CONTROL

GAS

MANIFOLD

BURNERS

SUPPLY

VENT DAMPER

DRAFT HOOD

BLOCKED VENT

SAFETY SWITCH

PRESSURE
RELIEF
VALVE

RETURN

Location and identification of parts

Advertising
This manual is related to the following products: