Slant/Fin TRDV Series User Manual

Page 10

Advertising
background image

10

INTREPID TRDV

TRDV-30-0.85

BF-5

0.85

3.21

0.65

70 W

Delavan

170

0

3.1

TRDV-30-1.00

BF-5

1.00

3.78

0.85

70 W

Delavan

140

0

4

TRDV-30-1.10

BF-5

1.10

4.16

0.85

70 W

Delavan

170

1

4

Boiler Model

Riello

Burner

Model

GPH

L/Hr

Size

(GPH)

Angle &

Type

Mfg.

Oil Pump

Pressure

Setting

“A”

Approx.

Head

Approx.

Air Band

Opening

Firing Rate No. 2 Oil

Nozzles

Model BF-5 Electrode Setting

Turbulator location

Picture 1

Turbulator Setting

Figure 8

Proper Insertion into Combustion Chamber

TURBULATOR SETTING

1. Loosen nut, 1, then turn the screw, 2, until the index marker, 3, is aligned with the correct index number.

2. Retighten the retaining nut, 1.

The numbers on the casting are there to denote the high and low end of the scale – For Model BF-5, zero and four are
scale indicators only. From left to right, the first line is 4 and the last line is 0.

The air/oil ratio depends on accurate setting of the turbulator disc and air damper.

Be careful when making this adjustment as an incorrect setting will result in an unsatisfactory operation.
See figure 8 & 9.

Figure 7

Figure 9

3

2

1

1/4”

RIELLO BURNER DATA – BURNER MODEL BF-5

Advertising