SmarTek Systems SAS-1 Relay Interface Configuration And Connection User Manual

Page 7

Advertising
background image

SmarTek Systems (www.smarteksys.com)

7

on the second SAS-RI to the RJA jack on the third SAS-RI. This pattern continues for up to 6
SAS-RI cards.

Note:

Each SAS-RI used as slaves (SAS0002 thru SAS0006) in Figure 6 must be factory

modified for receive only capability. They are not interchangable with the SAS-RI used as the
Master (corresponding to SAS0001).

Figure 7 shows the cabling for multiple shelf mount SAS-RIs connected to a single SAS-CT.
The cable used for the interconnects is standard straight thru CAT 5E cable with RJ-45
connectors on both ends. The cable is connected from the RJ-45 jack on the SAS-CT to the RJA
jack on the first SAS-RI (Master corresponding to SAS0001). The next cable is routed from the
RJB jack on the first SAS-RI to the RJA jack on the second SAS-RI. The next cable is routed
from the RJB jack on the second SAS-RI to the RJA jack on the third SAS-RI. This pattern
continues for up to 6 SAS-RI shelf mount units.

Data/Power Cable(s)

From SAS-1(s)

K

K+3

K+2

RJA

RJB

For

SAS0001

D 1

D 2

Card File Slot

SAS-CT

L

L+3

L+2

RJA
RJB

For

SAS0002

D 1

D 2

Card File Slot

SAS-CT To SAS-RI (RJA) Cable

(For Operation)

Data/Power Cable(s)

From SAS-1(s)

+

-

1

12

SAS Cabinet Termination

DC IN

Fuse

Power 8 to 24 VDC

1 NC
2

Blue

TxD+ (In)

3 Blk of Blu TxD- (In)
4

Green

RxD+ (Out)

5 Blk of Grn RxD- (Out)
6 NC
7 NC
8 NC
9 NC
10 Blk of Red GND
11

Red

VDC (Out)

12 Shield GND

Figure 6 Connecting Multiple Type 170 SAS-RI Cards to a Single SAS-CT

Advertising