SmarTek Systems SVS-1 User Guide-Part E User Manual

Page 27

Advertising
background image

Scenario 6 (Con’t) Set Output Relays For SDLC output from BIU#1

Select Detector Interface and Route Relays:
1)
Click the Detector Interface button to select the type of
detector/controller interface to be used ( BIU #1 SDLC ).
2) Click the Ph- button to select Phase group 2R. Note that
the line zones corresponding to the selected phase group
turn green. All others are magenta.
3) Click the D button to select the detector channel ( D8 )
this phase is routed to in the SDLC message.
4) Click the Ext= and the Dly= to select the Detection
Extension in seconds and the Detection Delay in seconds.
5) Click N, Or, And button to select logic for combining
(N=Not Used) Phase Groups into Detector Channels.
6) To clear the settings for the selected Phase group or for
all Phase groups click the Clear or the Clear All button.

5

1

2

3

76

4

BIU #1 SDLC Detector/Controller Interface with 3 Phases (Line Zone Groups)

Phase 5L, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D7
Phase 2T, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D8

Phase 2R, Detection Delay=2 sec, Detection Extension=0, Route to Detector Channel D8